background image

7

STEP 1

( Selecting Site )

Before installing your new  lift, check the following.

1. 

LIFT LOCATION

: Always use architects plans when 

available. Check layout dimension against floorplan 

requirements making sure that adequate space is 

available. 

2. 

OVERHEAD OBSTRUCTIONS

: The area where the 

lift will be located should be free of overhead obstructions 

such as heaters, building supports, electrical lines etc.

3. 

DEFECTIVE FLOOR

: Visually inspect the site where 

the lift is to be installed and check for cracked or defective 

concrete. 

4. 

OPERATING TEMPERATURE.

 Operate lift only 

between temperatures of 41° -104° F.

5. Lift is designed for

 INDOOR INSTALLATION ONLY.

 

STEP 2

( Floor Requirements )

This lift must be installed on a solid level concrete 
floor with no more than 3-degrees of slope. Failure 
to do so could cause personal injury or death.

A level floor is suggested for proper use and installa-

tion and level lifting. If a floor is of questionable slope,          

consider a survey of the site and/or the possibility of pour-

ing a new level concrete slab.

 

 

 

DO NOT

 install or use this lift on any asphalt surface   

      or any surface other than concrete.

 

 

 

 

 

DO NOT

 install or use this lift on expansion seams 

      or on cracked or defective concrete.

 

 

 

DO NOT

 install or use this lift on a second/elevated   

      floor without first consulting building architect.

 

 

 

DO NOT

 install or use this lift outdoors. 

CONCRETE SPECIFICATIONS

         

LIFT    

 

          CONCRETE 

MODEL                     REQUIREMENT

 

                               

P-6                    

                    4” Min. Thickness

P-6F 

             

                    4” Min. Thickness

     

   

DANGER! 

All models MUST be installed on 3000 PSI concrete only 

conformIng to the minimum requirements shown above. 

New concrete must be adequately cured by at least 

28 days minimum.

TOOLS REQUIRED

 

 

 

Rotary Hammer Drill Or Similar 

 

3/4” ; 1 1/4” Masonry Bits 

 

Hammer

 

4 Foot Level

 

Open-End Wrench Set: 1/2””,15/16” - 1-1/8”

 

 

 

Socket And Ratchet Set:  1-1/8”

 

Medium Crescent Wrench 

 

Crow Bar 

 

Chalk Line

 

 

 

Medium Flat Screwdriver

 

Tape Measure: 25 Foot Suggested

IMPORTANT NOTICE

These instructions must be followed to insure proper installation and operation of your lift. Failure 

to comply with these instructions can result in serious bodily harm and void product warranty. 

Manufacturer will assume no liability for loss or damage of any kind, expressed or implied resulting 

from improper installation or use of this product. 

PLEASE READ ENTIRE MANUAL PRIOR TO INSTALLATION.

Содержание BendPak P-6

Страница 1: ...operate or repair this equip ment without reading this manual and the important safety instructions shown inside Keep this operation manual near the machine at all times Make sure that ALL USERS read...

Страница 2: ...replace at their option for the warranty period those parts returned to the factory freight prepaid which prove upon inspection to be defective BendPak Inc will pay labor costs for the first 12 months...

Страница 3: ...the lift for correct initial function Read and follow the safety instructions Keep them readily available for machine operators Make certain all operators are properly trained know how to safely and c...

Страница 4: ...ecifications 8 Packing List 8 Main Assembly View Description of Parts 9 Floorplan Specifications 10 Step 3 Locating Lift 11 Step 4 Power Unit Location 12 Step 5 Flow Divider Hydraulic Hose Installatio...

Страница 5: ...or or bystander or damage to property or lift Failure to follow danger warning and caution instructions may lead to serious personal injury or death to operator or bystander or damage to property Plea...

Страница 6: ...irs Secure plug so that it cannot be accidentally plugged in during service 14 WARNING RISK OF EXPLOSION This equipment has internal arcing or sparking parts which shouldnotbeexposedtoflammablevapors...

Страница 7: ...se this lift on any asphalt surface or any surface other than concrete DO NOT install or use this lift on expansion seams or on cracked or defective concrete DO NOT install or use this lift on a secon...

Страница 8: ...d Hose Assy 12 7mm x 3130mm DS P 6 P 6F 5570148 8 3 4 x 4 WEJIT Anchor bolts 5530455 PACKING LIST When removing the lift from shipping pallet angles pay close attention as the lift assemblies can slid...

Страница 9: ...9 P 6 P 6F Main Assembly Views...

Страница 10: ...Pad Length 53 1346 mm 53 1346 mm Over Width 18 457 mm 18 457 mm Overall Length 81 2057mm 78 2057mm Lowered Height 4 102mm 4 102mm Lifting Time 35 Seconds 35 Seconds Motor 110 220 VAC 60HZ 1Ph 110 220...

Страница 11: ...ng engineer before installing this lift to make sure the floor is capable of sustaining the load 4 After selecting a site place each unit in position making sure that the hydraulic cylinders are place...

Страница 12: ...aftey valve Z bracket on the upper left mounting hole of the power unit bracket STEP 5 Flow Divider Hydraulic Hose Installation 1 Secure the hydraulic flow divider to a permanent wall or fixture usual...

Страница 13: ...the data plate found on the motor for proper power supply and wire size NOTE The standard power unit can be run on either 110V or 220V It is already wired for 110V and equipped with a 3 wire power cor...

Страница 14: ...OURCE OR PANEL AND CANNOT BE RE ENERGIZED UNTIL ALL MAINTENENCE AND OR INSTALLATION PROCEDURES ARE COMPLETED WARNING DO NOT run power unit with no oil Damage to pump can occur The power unit must be k...

Страница 15: ...so will void the warranty Cut the provided 1 4 air line tubing with a sharp blade to lengths as required Tubing must be cut square with no burrs Note To assemble air line tubing into fitting use firm...

Страница 16: ...six times The cylinders are self bleeding After bleeding system fluid level in power unit reservoir may be down Add more fluid if necessary to raise lift to full height It is only necessary to add fl...

Страница 17: ...down a few times to insure that the locks are engaging uniformly and that the safety release mechanisms are functioning POST INSTALLATION CHECK OFF Main Lift Assemblies Properly Shimmed And Stable An...

Страница 18: ...ith the frame or other recommended lifting point To Raise Lift Raise the lift by pressing the push button on the power unit Raise lift until the vehicles tires clear the floor Stop and check to make s...

Страница 19: ...LOWERING handle until the lift starts to descend Stay clear of lift area Ensure that both safeties are not engaged Fully lower the lift and remove all lifting adapters before driving vehicle away WEE...

Страница 20: ...an The vehicle manufacturer s recommendations should be used for spotting and lifting the vehicle LIFT OPERATION SAFETY It is important that you know the load limit Be careful that you do not overload...

Страница 21: ...ing lift KEEP HANDS AND FEET CLEAR Remove hands and feet from any moving parts Keep feet clear of lift when lowering Avoid pinch points ONLY TRAINED OPERATORS should operate this lift All non trained...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...start unit allowing possible contamination it to run for 15 seconds 4 Dirty oil Replace oil with clean Dexron ATF 5 Tighten all fasteners Tighten fasteners to recommended torques 6 Check for free mov...

Страница 25: ...new part Replace with new part 5 Reset circuit breaker fuse Reset circuit breaker fuse 6 Return unit for repair Return unit for repair 7 See Installation Manual See Installation Manual 8 Check wall ou...

Страница 26: ...e inlet hose assembly 3 Oil seal damaged or cocked Replace oil seal and install 4 Bleed cylinders See Installation Manual 5 See Installation Manual Consult Lift Manufacturer 6 Check vehicle weight Com...

Страница 27: ...lift all the way down 2 Oil seal damaged and cocked Replace oil seal around pump shaft 3 Bleed cylinder Refer to Installation Manual 4 Flush release valve Hold release handle down and start unit allow...

Страница 28: ...__________________________________________ ____________________________________________________________________ ____________________________________________________________________ ___________________...

Страница 29: ...29...

Страница 30: ...Main Parts View 30...

Страница 31: ...31 Air Valve Parts List...

Страница 32: ...For Parts or Service Contact BendPak Inc Ranger Products 1645 Lemonwood Dr Santa Paula CA 93060 Tel 1 805 933 9970 Toll Free 1 800 253 2363 Fax 1 805 933 9160 www bendpak com www rangerproducts com...

Отзывы: