OWNER’S MANUAL
37
SIXTY-TWO
Sensors
Fader Calibration
After cleaning or replacement, the sensors may get moved, affecting the contour. After any fader service,
perform this procedure to re-calibrate the faders and crossfader.
1. Power off the Sixty-Two.
2. Move all faders to the center-most position.
3. Push down both
DECK 1 CUE
and
DECK 2 CUE
buttons at the same time.
4. While holding these buttons down, power on the Sixty-Two.
5. Immediately after powering up, the
CUE
lights will flash one time, indicating a successful calibration.
If the
CUE
lights flash three times, the sensors may have moved too far or all faders were not properly
centered, and the faders cannot correctly calibrate.
Problems?
Contact Rane Corporation customer service at 425-355-6000 or email us at [email protected].
Online help is available at
dj.rane.com
.