- Section 3: Page 15 -
EGRO 55 SERIES TECHNICAL MANUAL
©
Copyright 2008. Rancilio North America
E55_TM_programmingV3
3.5 CONFIG 2 MENU
Config1...
Service...
Products...
Config2...
X
X
X
Product Total
X
Uploads the settings from a service card to the Products, Confi g1, and Confi g2 menus of the machine.
ONLY VALID WITH A CARD READER ATTACHED TO THE MACHINE.
Overwrites the current settings in Products, Confi g1 and Confi g2 with factory default settings.
DO NOT USE OR YOU WILL HAVE TO REPROGRAM THE ENTIRE MACHINE!!
NOT USED IN USA!
Enables or disables loading of drink prices into a CCI peripheral.
0 = Disabled
1 = Enabled
Enables or disables the Shift (#1) button. Enable when DECAF is an option.
0 = Disabled
1 = Enabled
NOT USED IN USA!
Enables or disables the Choko function.
0 = Disabled
1 = Enabled
Enables or disables the Milk sensor, Bean sensor, and Grounds counter feature.
NOTE: ONLY the Grounds counter
feature is available in the USA. It measures the grounds in the brew chamber, if there is not enough to brew the selected drink it
displays a “Check Beans” message.
Turns beeper ON or OFF.
0 = ON
1 = OFF
NOT USED IN USA!
Enables or disables cleaning when machine’s in operating mode 2.
0 = rinsing disabled
1 = rinsing enabled
Specifi es which MLR (Milk Line Rinsing) System is being used.
0 = none MLR
1 = MLR 1. Older generation rinsing with Hose cleaning
2 = MLR 2. Older generation rinsing without Hose cleaning
3 = MLR 3. Used with European under-counter solution
4 = MLR 4 Use with USA cool box solution -- pipes are fl ushed with water without steam
5 = MLR 5. Used KS 6 above counter fridge -- RECOMMENDED SETTING
Load Card?
Load Defaults
Price=> CCI
Shift
Choko
IMS Beeper
R-Mode 2
MLR_Type
MB_Sensor
USED FOR
MODEL 5513
ONLY
USED FOR
MODEL 5513
ONLY
Applies to software versions 1.0 - 2.09
0 = Grounds counter feature Enabled
1 = Milk, Bean sensor and Grounds counter enabled
2 = Only Milk sensor enabled
Applies to software versions 2.10 and greater
0 = Grounds counter feature Enabled
1 = Milk, Bean sensor and Grounds counter enabled
2 = Nothing activated
3 = Milk sensor only
Confi g 2 Menu contains parameters for making adjustments to the machine that do not effect the specifi c drink parameters.
Содержание EGRO 55 Series
Страница 2: ...This page is intentionally left blank...
Страница 4: ...This page is intentionally left blank...
Страница 6: ...This page is intentionally left blank...
Страница 13: ...This page is intentionally left blank...
Страница 26: ...This page is intentionally left blank...
Страница 56: ...This page is intentionally left blank...
Страница 66: ...This page is intentionally left blank...
Страница 74: ...This page is intentionally left blank...