3.8 ERROR LIST - CONTINUED
3.8 ERROR MESSAGES -continued
NO.
DESCRIPTION
SOLUTION
93
Lower piston (P2) can not reach it’s
maximum height.
a.
Check lower spindle motor (M8) - use monitor menu
b.
Revolution counter (S16) is faulty
94
Lower piston (P2) height has
exceeded it’s maximum height
during brewing. (Motor exceeded
100 revolutions)
a.
Check lower piston spindle motor - use monitor menu
b.
Revolution counter (S16) is faulty
c.
Increase upper piston height (P1) by 2 in Confi g 1 menu, P1 Turns parameter
97
No signal from upper piston (P1)
limit switch (S14)
a.
Check the upper spindle motor (M7) - use the monitor menu
b.
Revolution counter (S14) is faulty
c.
Check fuse F5
98
No signal from lower piston limit
switch (S14).
a.
Check the lower spindle motor (M8) - use the monitor menu
b.
Revolution counter S16 is faulty
111
Short circuit on temperature sensor
for coffee boiler (NTC B1)
a.
Check wiring to sensor
b.
Check the J11 Pin 1/2 connection on the mainboard
121
Failure of the temperature sensor for
the coffee boiler (NTC B1)
a.
Check wiring to sensor
b.
Check the J11 Pin 1/2 connection on the mainboard
Содержание EGRO 55 Series
Страница 2: ...This page is intentionally left blank...
Страница 4: ...This page is intentionally left blank...
Страница 6: ...This page is intentionally left blank...
Страница 13: ...This page is intentionally left blank...
Страница 26: ...This page is intentionally left blank...
Страница 56: ...This page is intentionally left blank...
Страница 66: ...This page is intentionally left blank...
Страница 74: ...This page is intentionally left blank...