19
RAM 100 • 1000 • 5500
RAMSET
www.ramsetinc.com
Terminal # 1 - COMMON
Low voltage common.
TERMINAL 2 - SAFETY
Stops the gate from closing.
- GATE OPEN - Holds gate open.
- GATE CLOSED - Gate stays closed.
- GATE OPENING - Gate continues to open.
- GATE CLOSING - Gate stops, then opens.
The function can be altered with Dip Switch B5
(see dip switch configuration). Used with loop
detectors, photo eyes, safety edges...etc.
Becomes active with a closed contact to com-
mon.
Terminal # 3 - CLOSE
Closes the gate.
Used with 3-button stations or pushbuttons.
Becomes active with a closed contact to com-
mon.
Terminal # 4 - FIREBOX
Opens the gate with a maintained signal. Used
with fire dept. key switches & controls. Becomes
active with a closed contact to common. Closes
immediately after the closed contact to common
is removed.
Terminal # 5 - EXIT
Opens the gate.
Uses with exit loop detectors, phone entry
systems,keypads, 3-button stations...etc.
Becomes active with a closed contact to com-
mon.
Terminal # 6 - PHANTOM
Holds the gate open when the open limit switch
is active.
Covers the area of a swing gate’s path.
Used with loop detectors and photo eyes.
Becomes active with a closed contact to com-
mon.
Terminal # 7 - RADIO
Opens, closes and/or stops the gate.
Operation depends on dip switch B8 & A1-3 (see
dip switch configuration).
Used with an RF reciever, pushbutton, keypad...
etc.
Becomes active with a closed contact to com-
mon.
Terminal # 8 - EDGE
When triggered the gate will stop and remain
stopped until the detector is cleared. Once the
detector is cleared, the operator will resume
normal operation. If triggered twice during one
travel, the control board will lock up and the
alarm will sound for 6 minutes. After 6 minutes
the unit will return to normal operation.
Becomes active with a closed contact to com-
mon.
Terminal # 9 and 10 - LIMIT 1 & LIMIT 2
Stops the gate in either the fully open or fully
closed position.
Direction depends on dip switch A4 (see dip
switch configuration).
Factory wired and should not be moved.
Becomes active with a closed contact to com-
mon.
Terminal # 11 and 12 - COMMON
Low voltage common.
Terminal # 13 - 24 VAC
Provides 24 VAC for peripheral accessories.
Terminal # 14 and 15 - MAG1 & MAG2
Provides a closed contact when the gate is clos-
ing or closed (like a switch).
Used with a Magnetic Lock.
Needed: A power supply that is rated for the
magnetic lock that is being connected. Make
sure the power supply is the right voltage and
current rating. See wiring diagram on previous
page.
TERMINAL 16 - SLOW
Only available on the All Secure rail drive opera-
tor.
Creates a slow stop using the slow stop switch
mounted in the operator.
Factory wired and should not be moved.
Terminal # 17 and 18 - MOTOR 1 & MOTOR 2
Factory wired and should not be moved.
Supplies voltage to the motor.
Direction depends on dip switch A4 (see dip
switch configuration).
Terminal # 19 and 20 - AC HOT & NEUTRAL
115 VAC AND 230 VAC to power the operator.
Factory wired and should not be moved.
TERMINAL STRIP CONNECTIONS