RESPONSIBILITIES OF INSTALLERS AND TECHNICIANS cont.

•  WARNING SIGNS MUST BE PERMANENTLY AFFIXED TO THE GATE PANEL IN A HIGHLY VISIBLE 

PLACE THAT CAN BE EASILY SEEN FROM BOTH SIDES OF THE GATE.

•  A SEPARATE ENTRANCE IS SUPPLIED FOR PEDESTRIANS. THE OPERATOR IS INTENDED FOR 

INSTALLATION ONLY FOR GATES USED FOR VEHICLES.

•  THE GATE MUST BE INSTALLED IN A LOCATION SO THAT ENOUGH CLEARANCE IS SUPPLIED 

BETWEEN THE GATE AND ADJACENT STRUCTURES WHEN OPENING AND CLOSING TO 

REDUCE THE RISK OF ENTRAPMENT.

•  ALL CONTROLS MUST BE LOCATED AT LEAST 6 FEET AWAY FROM ANY PART OF THE GATE 

OPERATOR OR MOVING GATE AT ALL TIMES.

•  INTERIOR CONTROL STATIONS SHOULD BE INSTALLED SO THAT THE USER HAS A DIRECT 

LINE OF SIGHT TO THE GATE AREA BEING CONTROLLED.

•  PHOTOCELLS SHOULD BE INSTALLED WITHIN 5 INCHES FROM THE GATE PANEL AND A 

MAXIMUM HEIGHT OF 27.5 INCHES.

•  A PHOTOCELL IS A SAFETY DEVICE FOR PEDESTRIANS ONLY; VEHICLE DETECTORS SHOULD 

ALWAYS BE USED FOR DETECTION OF MOTOR VEHICLES.

•  NO SAFETY DEVICES SHOULD EVER BE BYPASSED, REMOVED OR OMITTED BY THE 

INSTALLER/TECHNICIAN. A SIGNED WAIVER DOES NOT NULIFY THE INSTALLER/TECHNICIANS 

LIABILITY DUE TO THE FACT THAT IT HAS NO SUBSTANCE IN LITIGATION INVOLVING AN 

INJURED PARTY WHO DID NOT SIGN THE WAIVER.

•  IF YOU ARE INSTALLING THE OPERATOR ON A GATE THAT DID NOT HAVE AN OPERATOR ON 

IT, THE GATE MUST CONFORM TO THE CURRENT ASTM F 2200 STANDARDS.

•  IF YOU ARE INSTALLING THE OPERATOR ON A GATE THAT ALREADY HAD AN OPERATOR ON 

IT, THE TECHNICIAN/INSTALLER SHOULD ADVISE THE CUSTOMER OF THE UPGRADES THAT 

ARE NEEDED TO BRING THE GATE UP TO THE CURRENT ASTM F 2200 STANDARDS.

•  WHEN INSTALLING OR WORKING ON A GATE OPERATOR SYSTEM, ALWAYS MAKE SURE 

THAT THE AREA AROUND YOU IS SECURE. USE CONES, YELLOW CAUTION TAPE OR WHEN 

POSSIBLE, BLOCK OFF THE DRIVEWAY FROM TRAFFIC.

•  WHEN NECESSARY, INSTALL SURGE/LIGHTNING SUPPRESSION AND GROUND RODS.

•  ALL AREAS THAT ARE AT RISK OF ENTRAPMENT SHOULD BE PROTECTED BY AN ANTI-

ENTRAPMENT DEVICE.

•  MAKE SURE TO INSTALL POSITIVE STOPS ON THE FULL OPEN & IF NECESSARY, ON THE FULL 

CLOSED.

•  ALWAYS REMEMBER, YOU ARE THE TRAINED PROFESSIONAL AND WHAT A CUSTOMER 

WANTS SHOULD NEVER SUPERCEDE SAFETY.

Содержание RAM 100

Страница 1: ...RAM 100 1000 5500 RAMSET www ramsetinc com...

Страница 2: ...www ramsetinc com...

Страница 3: ...PERLY MAINTAINED Read the owner s manual Have a qualified service person make repairs to gate hardware 7 The entrance is for vehicles only Pedestrians must use separate entrance 8 SAVE THESE INSTRUCTI...

Страница 4: ...ONCERN WHEN INSTALLING A GATE OPERATOR INSURE A SAFE AND PROPER INSTALLATION FOLLOWING ALL BUILDING FIRE ELECTRICAL PROPERTY MAINTENANCE ASTM F 2200 AND UL 325 SAFETY CODES ONLY USE UL 325 COMPLIANT A...

Страница 5: ...OF MOTOR VEHICLES NO SAFETY DEVICES SHOULD EVER BE BYPASSED REMOVED OR OMITTED BY THE INSTALLER TECHNICIAN A SIGNED WAIVER DOES NOT NULIFY THE INSTALLER TECHNICIANS LIABILITY DUE TO THE FACT THAT IT H...

Страница 6: ...cessi ble by authorized personnel e g fire police EMS may be placed at any location in the line of sight of the gate g The Stop and or Reset button must be located in the line of sight of the gate Act...

Страница 7: ...ate Operator 3 11 A vehicular gate operator or system intended for use in an industrial location or building such as a factory or loading dock area or other locations not accessible by or intended to...

Страница 8: ...ER FAILURE RELEASE Exclusive Foot Pedal Release RPI TL only Exclusive foot pedal release or optional battery back up system BBS or RPI TL Exclusive foot pedal release or optional battery back up syste...

Страница 9: ...e based on soil bearing shear of 2000 P S F These figures may have to be ad justed depending on local soil conditions 1 Construct form for mounting pad according to dimen sions shown in Figure 1 2 and...

Страница 10: ...your gate RAM 100 IS FOR FRONT INSTALLATION ONLY FOR CENTER OR REAR INSTALLATIONS A RAM 1000 5500S IS NEEDED NOTE Your operator will not respond until your gate is properly engaged Gate Disengaged Fig...

Страница 11: ...hese figures may have to be adjusted depending on local soil conditions 1 Construct form for mounting pad according to dimensions shown in Figure 6 7 and 8 2 Locate mounting pad according to dimension...

Страница 12: ...WN Fully Open No tail on gate required FRONT INSTALLATION GATE SHOWN Closed Tail on gate required Top View Front View Top View Front View Hidden Wall Wall TAIL Inside Property Inside Property Inside P...

Страница 13: ...ct sensor photoelectric sensor or equivalent and a contact sensor edge device or equivalent is required on each individual installation to comply with UL325 WARNING To adjust gate travel depress sprin...

Страница 14: ...a qualified and trained technician to determine All Possible Entrapment areas locations The amount and type of entrapment protection devices that are needed Approved anti entrapment devices Miller s E...

Страница 15: ...not be present or a fault condition occur that precludes the sensing of an obstruction including an interruption of the wireless signal to the wireless device or an open or short circuit in the wiring...

Страница 16: ...g when lit check mag lock transformer voltage on mag lock mag lock OFF De energized when gate is opening or opened 19 20 Full Open Full Closed ON Gate is on a limit Check dip switch A4 make sure the c...

Страница 17: ...verify proper system operation when installing or servicing an operator Opening Opens the gate Stop Stops the gate Closing Closes the Gate RESETTING THE E R D Electronic Reversing Device With power o...

Страница 18: ...the safety input is triggered and then cleared the gate will immediately start closing If the safety input is then activated again before the gate is fully closed the gate will stop and stay at rest u...

Страница 19: ...de 1 Stop input plug bypass ON Bypass Mode OFF Active Mode Manual ERD adjustments Range 0 to 7 0 Most Sensitive 7 Least Sensitive Switches from automatic ERD adjustment Dip switch C7 C8 and Manual ERD...

Страница 20: ...E SAFETY LOOP DET SAFETY EDGE SENSOR FIRE BOX EXIT LOOP PHONE ENTRY KEYPAD OPEN ONLY PHANTOM LOOP RADIO RECEIVER KEYPAD OPEN CLOSE EDGE SENSOR LIMIT SWITCH 2 SLOW STOP SWITCH 115 OR 230 VAC 1HP MOTOR...

Страница 21: ...on Terminal 8 EDGE When triggered the gate will stop and remain stopped until the detector is cleared Once the detector is cleared the operator will resume normal operation If triggered twice during o...

Страница 22: ...pen Used with 3 buttons station Primary Secondary Connection Synchronizes movement between two gates 3 wires A B C Monitored Anti Entrapment Device Mandatory entrapment protection device APPROVED ANTI...

Страница 23: ...from the primary unit to the secondary unit 1 Wire from JP2 7 to Power supply 2 Wire from JP2 8 to light siren 3 Wire from power supply to light siren 24VAC 1A max current draw 1 Wire from JP2 5 to Po...

Страница 24: ...22 RAMSET www ramsetinc com RAM 100 1000 5500 PARTS DIAGRAM RAM 100 3 16 1 13 14 28 10 36 8 11 23 24 19 15 27 31 5 32 25 21 34 40 38...

Страница 25: ...23 RAM 100 1000 5500 RAMSET www ramsetinc com RAM 1000 RAM 5500 2 28 17 18 25 31 13 14 12 15 9 20 27 26 24 23 35 30 22 21 29 4 39 33 5 6 7 PARTS DIAGRAM 41 37...

Страница 26: ...itch Rocker 1 1 1 23 800 63 00 Control Board Intelligate Domestic UL 1 1 1 1 24 800 64 00 Edge Connector 20 Pin 1 1 1 1 25 800 64 50 Radio Receiver Terminal 1 1 1 1 26 800 66 00 Lexan Control Board Co...

Страница 27: ...cker 1 1 1 40 800 75 65 CHAIN KIT R100 1 800 38 16 Nut Hex Head 1 2 4 800 52 02 Chain 41 10ft per box 2 800 52 30 Chain Bolt 1 2 13 x 3 1 4 2 800 52 51 Master Link 41 1 800 54 15 Bracket Chain Left 3...

Страница 28: ...ect or stop when an object activates the non contact sensors After adjusting the force or the limit of travel retest the gate operator Failure to adjust and retest the gate operator properly can incre...

Страница 29: ...gate The entrance is for vehicles only Pedestrians should use a separate entrance Use the emergency release only when the gate is not moving Make sure before using the foot pedal release the circuit b...

Страница 30: ...transmitters 2 Remove receiver If problem persist contact Ramset GATE DOESN T OPEN 1 Radio L E D On 2 10 amp fuse blown 3 Opening accessory not functioning 1 See above symptoms solutions 2 Check repl...

Страница 31: ...9116 De Garmo Ave Sun Valley CA 91352 Tel 818 504 2533 Fax 818 504 1141 www ramsetinc com...

Отзывы: