background image

SYMPTOM 

   POSSIBLE PROBLEMS      SERVICE

Preparing Tool for Operation—Battery/Charger Problems  

Normal Stage of Operation  

Pre-Combustion/Combustion Stage of Operation 

 

 

 

 

 

 

 

 

 

 

 

 

 

— Fan does not run 

—tool LED is off .

— Fan does not run, or  

runs slower than normal 
—tool LED is red .

— Battery is not charged .

— Battery Terminals or 

Magazine battery contacts 
are oily, dirty, or corroded . 

— Battery is discharged .

— Charge Battery according to Operating Manual . 
    

   

— Clean Battery terminals . Clean Magazine Battery 

terminals as required . 
  

   

 

  

    

 

— Charge Battery .  

 

TROUBLESHOOTING

TROUBLESHOOTING

15

— Safety Yoke does not 

depress fully—tool 
does not operate . 

— Tool will not cycle-fan 

runs, LED is green . 

— Head or Sleeve O-Ring 

pinched . 

— Fuel Cell is empty .

— Spark Wire out of spark 

plug .

— Spark does not occur .

— Contact Authorized Ramset Distributor Sales 

Representative for service .

— Replace Fuel Cell . 

— Contact Authorized Ramset Distributor Sales 

Representative for service .

— Contact Authorized Ramset Distributor 

Sales Representative for service .

— Battery does not appear 

to accept charge . Green 
charger light does not 
come on .

— Flashing lights on  

charger base unit .

— Inoperative indicator 

lights on charger .

— Battery damaged or 

cycle life exhausted .

— Damaged charger . 

— Damaged Battery

— Try Battery in tool after 3 hours on charge cycle . 

If tool LED is green, charger lights are not working 
properly . Replace charger, monitor charging time 
to ensure Battery has adequate time for recharging .  
It’s normal for Battery to feel warm after properly 
charging . 

— Replace Battery .

— Discontinue use immediately and unplug from 

power source . Replace charger and tag or  
dispose of charger to prevent accidental reuse   
or connection to power source .

— Replace Battery

Содержание GYPFAST

Страница 1: ...RAMSET GYPFAST OPERATOR S SAFETY OPERATING INSTRUCTION MANUAL DANGER READ AND OBEY ALL SAFETY AND OPERATING INSTRUCTIONS BEFORE OPERATING TOOL GAS POWERED LOW VELOCITY PISTON TYPE FASTENING TOOL...

Страница 2: ...ents Each section of the manual is written with you the tool operator in mind We have left out all of the technical terms so that you can readily understand how to get the maximum performance from you...

Страница 3: ...d Filter the Motor Housing the Nose and the Safety Yoke The Magazine Assembly contains the Magazine Magazine Dow and Hinge Pin SPECIFICATIONS Dimension Height 16 inches Length 13 inches Weight 7 9 pou...

Страница 4: ...sing flammable gas This tool must be operated only in a well ventilated environment because the tool exhausts carbon monoxide similar to a gas chain saw or lawnmower Exposure to carbon monoxide may ca...

Страница 5: ...NOT LOAD FASTENERS WITH THE TRIGGER OR SAFETY YOKE DEPRESSED When loading fasteners into the GypFast tool you must avoid pulling the Trigger or while having the Safety Yoke depressed When the tool is...

Страница 6: ...49 C may cause the Fuel Cells to leak or burst releasing the flammable gases and creating a risk of fire or explosion 17 FUEL CELL DISPOSAL Never attempt to puncture crush burn or refill a Fuel Cell...

Страница 7: ...r area Ramset s involvement in this program is part of our commitment to preserving our envi ronment and conserving our natural resources CHARGING INSTRUCTIONS 1 Connect the round plug of the wall mou...

Страница 8: ...llustration is a closeup of the side of the GypFast tool On the side of the Handle is a small plastic lens This is the Battery Voltage Indicator Light To check the battery voltage the LED on the right...

Страница 9: ...queezes the inner fuel container much as you squeeze a tube of toothpaste This squeezing action ensures that all the fuel is used and that the GypFast tool can operate in any position Because of this...

Страница 10: ...er Assembly and pushing down until the Actuator Cover snaps into position OUTDOOR WEATHER AND THE GYPFAST TOOL Use the GypFast tool outdoors in clear weather when the Tool Fuel Cell and Battery are be...

Страница 11: ...3 RELEASE TRIGGER LIFT THE TOOL The Combustion Chamber opens Fan exhausts hot gases and cools internal components NOTE If no additional cycles are made fan will run for 7 seconds and then shut off TO...

Страница 12: ...D in the Handle of the GypFast tool When encountering a problem the first step should always be to make sure the Battery has enough energy to operate the tool If the light is red recharge the Battery...

Страница 13: ...the outside of the tool using a soft cloth and a mild degreasant like paraffin CAUTION Never use highly volatile solvents such as gasoline to clean the tool Do not allow any solvent to enter the inte...

Страница 14: ...3 Place the Battery in its Charger only if it needs charging as indicated by the red charge light in the handle 4 Wipe your GypFast tool with a clean soft cloth 5 Check Adjustable Nosepiece Element to...

Страница 15: ...not occur Contact Authorized Ramset Distributor Sales Representative for service Replace Fuel Cell Contact Authorized Ramset Distributor Sales Representative for service Contact Authorized Ramset Dis...

Страница 16: ...e minute Pull trigger If fastener does not drive there is a leak that requires service Use only fasteners meeting Ramset specifications Clear jam according to Operating Manual Check Fuel Cell accordin...

Страница 17: ...is warranty does not apply to part replace ment required due to normal wear This warranty is void as to any tool which has been subjected to misuse abuse accidental or intentional damage use with fast...

Страница 18: ...NTER VISIT OUR WEB SITE AT WWW RAMSET COM OR CALL 800 241 5640 Concrete Fastening Systems Glendale Heights IL 60139 800 RAMSET6 1 800 726 7386 www ramset com Buy with Confidence Buy From Your Authoriz...

Отзывы: