28
MAINTENANCE INSTRUCTIONS
A qualified service agency should conduct an annual inspection and maintenance of your VIVA L including the
overall installation and venting to keep it running safely. The following procedures should be performed only by a
qualified service person. The gas supply should be turned off and the stove should be completely cool whenever a
maintenance procedure is performed. All parts of the appliance that are removed for servicing must be replaced prior
to operation.
ONLY an authorized qualified installer may open the door/remove the glass. The end user must NOT open the
door/remove the glass, as this may be unsafe and may result in voiding the manufacturer’s warranty.
TURN OFF the gas before servicing the appliance. It is recommended that a qualified service technician perform an
appliance check-up/service once a year.
Any safety screen or guard removed for servicing MUST BE REPLACED before operating this appliance.
DO NOT USE this appliance if any part has been under water. Immediately, call a qualified service technician to
inspect the unit and to replace any part of the control system and any gas control that has been under water.
Any alteration to the product that causes soot or carbon to form and results in damage is not the responsibility of the
manufacturer.
INSPECT the external vent cap on a regular basis to make sure that no debris, plants, trees, shrubs are interfering
with the air flow.
CLEANING THE GLASS
WARNING: Never clean the glass while it is hot. Do not use abrasive cleaners or cleaners containing
ammonia.
NOTE: A micro-fiber cleaning cloth and plain water is recommended by the glass manufacturer.
Burner Maintenance
The flames from the burner should be visually checked.
The flame should be blue and yellow in color and candle-like in appearance.
Pilot Maintenance
The pilot flame must be visually checked. The pilot flame must always be present when the appliance is in operation.
The pilot burner has two distinct flames, one engulfing the thermocouple, the other reaches across to the main burner.
WARNING: Do not operate the appliance with the glass front removed, cracked or broken.
Replacement of the glass should be done by a qualified service person.
WARNING: Use only door assembly, P/N xxxxxxx which includes the glass panel, frame and gasket.
Do not use substitute materials. Do not strike or slam the glass front.
29
The area around the injector should be inspected and any lint or foreign material must be removed with a brush or
vacuum.
Thermocouple Maintenance
The thermocouple completeness and operation must be checked.
The qualified engineer must confirm that the thermocouple is in place and not cracked or damaged.
Main Burner Injector Details
See details on page 6 or Injector (Orifice) Numbers.
Содержание VIVA L Series
Страница 7: ...13 Vertical Roof Termination on angle 14 Vertical Roof Termination with bends...
Страница 14: ...24 25...
Страница 15: ...26 27...
Страница 19: ...31 Viva 100 LG with side glass 32 Viva 120 L without side glass...
Страница 20: ...33 Viva 120 LG with side glass 34 Viva 160 L without side glass...
Страница 21: ...35 Viva 160 LG with side glass 36 Appendix 2 Mertik Symax controls...