9
The VIVA L Gas Stove has been tested and listed for installation with 4” X 6 5/8” Simpson DuraVent GS
®
,
AmeriVent Direct
®
, Selkirk DT
®
, BDM Pro-Form DVS
®
, ICC EXCEL Direct
®
and OLYMPIA CHIMNEY SUPPLY
Ventis
®
direct venting components.
For specific installation requirements, follow the installation instructions included
by the venting manufacturer with the venting system components you have chosen. The total vent length may not
exceed 50 feet (15m), including vertical rise and horizontal run. The vent lengths are measured from the stove, not
the floor. The minimum vertical vent rise when using a vertical vent termination is 2 feet (600mm). The minimum
vertical rise required when using a horizontal vent termination is 2 feet (600mm). The maximum allowed horizontal
vent run is 12 feet (3.6m).
The VIVA L is shipped with a Simpson DuraVent GS
®
starter section that is specifically designed for the VIVA L.
Regardless of the venting brand you chose, you must use the DuraVent starter section that was provided with your
stove. All of the venting brands listed for use with the VIVA L are compatible with the provided starter section. For
venting system installation details, refer to the instructions provided with the venting system you have chosen. Each
brand has specific installation requirements that must be followed to insure a safe and functional venting system for
your VIVA L.
SEE PAGE 13 FOR INFORMATION ABOUT REAR VENTING DIRECTLY THROUGH THE
WALL TO A HORIZONTAL VENT TERMINATION.
10
Horizontal Wall Vent Termination
Flue sizing:
VIVA L
:
Ø4x6
⅝
Connector on Appliance.
Ø4x6
⅝
Maybe used Throughout, Alternatively,
Ø5x8 Expander may be used, so that Ø5x8 flue can be used thereafter.
Flue Terminal:
Ø4x6
⅝
Alternatively, Ø5x8
Maximum pipe extension, for outside wall (H)
= 4 X Vertical Pipe Rise (V) -1. For
Ø5x8 flue.
= 2 X Vertical Pipe Rise (V) . For
Ø4x6
⅝
flue.
Maximum Permissable run (H) =50 feet (15m).
Vertical Rise
Horizontal Run
Horizontal Run
Ø5x8 Flue
Ø 4x6⅝ Flue
Feet
metres
Feet
metres
Feet
metres
1'
0.3
3' 5"
1.1
2'
0.6
2'
0.6
7' 6"
2.3
4'
1.2
3'
0.9
11' 6"
3.5
6'
1.8
4'
1.2
15' 6"
4.7
8'
2.4
5'
1.5
19' 6"
5.9
10'
3.0
6'
1.8
23' 6"
7.2
12'
3.7
7'
2.1
27' 6"
8.4
14'
4.3
8'
2.4
31' 6"
9.6
16'
4.9
9'
2.7
35' 6"
10.8
18'
5.5
10'
3.0
39' 6"
12.0
20'
6.1
11'
3.4
43' 6"
13.3
22'
6.7
12'
3.7
47' 6"
14.5
24'
7.3
13'
4.0
50'
15
26'
7.9
14'
4.3
50'
15
28'
8.5
15'
4.6
50'
15
30'
9.1
16'
4.9
50'
15
32'
9.8
17'
5.2
50'
15
34'
10.4
18'
5.5
50'
15
36'
11.0
19'
5.8
50'
15
38'
11.6
20'
6.1
50'
15
40'
12.2
21'
6.4
50'
15
42'
12.8
22'
6.7
50'
15
44'
13.4
23'
7.0
50'
15
46'
14.0
24'
7.3
50'
15
48'
14.6
25'
7.6
50'
15
50'
15
Minimum Vertical Flue Height:
-
2 feet (600mm)
Flue Restrictors to be fitted, Ø
4x6⅝:
Vertical Rise < 3 feet (1m)
-
No Restrictor
Vertical Rise 3 – 8 feet (1-2m)
-
35mm Restrictor
Vertical Rise > 8feet (2m)
-
50mm Restrictor
Содержание VIVA L Series
Страница 7: ...13 Vertical Roof Termination on angle 14 Vertical Roof Termination with bends...
Страница 14: ...24 25...
Страница 15: ...26 27...
Страница 19: ...31 Viva 100 LG with side glass 32 Viva 120 L without side glass...
Страница 20: ...33 Viva 120 LG with side glass 34 Viva 160 L without side glass...
Страница 21: ...35 Viva 160 LG with side glass 36 Appendix 2 Mertik Symax controls...