25 / 34
OPERATING INSTRUCTIONS
FOR OEM USE ONLY
© 2016 Mertik Maxitrol GmbH & Co. KG,
All Rights Reserved.
PROGRAM MODE
1 2
ON
AM
PM
OFF
ON:
Press button. , or ,
or
displayed.
1 2
ON
AM
PM
OFF
OFF:
1. Press
or or button to enter
Manual Mode.
2. Press button to enter Thermostatic
Mode.
NOTE:
The set temperature for Thermostatic Mode is the tem-
perature for the on time in Program Mode. Changing the
Thermostatic Mode set temperature also changes the
on time temperature in Program Mode.
Default settings:
ON TIME (Thermostatic) TEMPERATURE: 21 °C (70 °F)
OFF TIME TEMPERATURE: “
” (pilot flame only)
1 2
ON
AM
PM
OFF
TEMPERATURE SETTING:
1. Press
button and hold until
flashes.
and set temperature (set-
ting in Thermostatic Mode) displayed.
2. To continue press button or wait.
,
displayed, temperature flash-
es.
3. Select off temperature by pressing
the or button.
4. To confirm press button.
NOTE:
The on (Thermostatic) and off set temperatures are the
same for each day.
1 2
ON
AM
PM
OFF
DAY SETTING:
5. flashes. Press or button to
choose between
,
, , , , ,
, , .
6. To confirm press button.
MODES of OPERATION
1 2
ON
AM
PM
OFF
Thermostatic Mode
The room temperature is measured and
compared to the set temperature. The
flame height is then automatically ad-
justed to achieve the set temperature.
1 2
ON
AM
PM
OFF
Program Mode
PROGRAMS 1 and 2, each can be pro-
grammed to go on and off at specific
times at a set temperature.
AM
Eco Mode
Flame height modulates between high
and low. If the room temperature is low-
er than the set temperature, the flame
height stays on high for a longer period
of time. If the room temperature is high-
er than the set temperature, the flame
height stays on low for a longer period
of time. One cycle lasts approx. 20 min.
THERMOSTATIC MODE
1 2
ON
AM
PM
OFF
ON:
Press button. displayed, preset tem-
perature displayed briefly, and then room
temperature displayed.
OFF:
1. Press button.
2. Press or button to enter Manual
Mode.
3. Press button to enter Program Mode.
4. Press button to enter Eco Mode.
1 2
ON
AM
PM
OFF
SETTING:
1. Press
button and hold until dis-
played, temperature flashes.
2. To adjust set temperature press or
button.
3. To confirm press button or wait.
Содержание VIVA L Series
Страница 7: ...13 Vertical Roof Termination on angle 14 Vertical Roof Termination with bends...
Страница 14: ...24 25...
Страница 15: ...26 27...
Страница 19: ...31 Viva 100 LG with side glass 32 Viva 120 L without side glass...
Страница 20: ...33 Viva 120 LG with side glass 34 Viva 160 L without side glass...
Страница 21: ...35 Viva 160 LG with side glass 36 Appendix 2 Mertik Symax controls...