Rain Master Irrigation Systems
RME EAGLE User Manual
Chapter 4 Controller and Front Panel Operation
Page 31
Each day at midnight the controller will count down by one day until it reaches zero and returns to
the Automatic Mode.
EXAMPLE:
To clear the programmable Rain Mode,
Press:
The controller will return to the Automatic Mode.
Note: No watering will occur when the controller returns to the Automatic Mode if you
have also placed the Rain Switch in the “NO WATERING” position.
4.1.3 Programmable Operations Mode
In the Programmable Operations Mode the controller is running the user entered irrigation
programs. The controller will display the irrigation program number in the PROMPT/MESSAGE
display and the current station will be displayed in the STATIONS/DAYS display.
The lapsed time of the station will be displayed and continue to be displayed until the count-down
reaches zero, the station will turn off and the next station will start.
If flow sensing is enabled, the display will alternately display the flow rate for 3 seconds and then
the station’s lapsed time will be displayed for 3 seconds and the cycle will repeat.
4.1.4 Programming Mode
In the Programming Mode the controller is awaiting programming parameters to be provided. The
controller is in this mode during program, configuration, and setup data entry.
The RME EAGLE keyboard is organized into three major key categories, as depicted in Figure 12 -
RME EAGLE Keyboard Configuration. Each keyboard groups assists you in programming,
controlling, and reviewing the various functions of the RME EAGLE controller.
2 1:44:30
PROGRAM
114 GPM
PROGRAM
QUIT