Rain Master Irrigation Systems
RME EAGLE User Manual
Chapter 6 Setup Key Operations
Page 65
Press:
Add
Programs
2
and
4
to
the
Pump configuration.
Display will indicate:
Subsequent presses of Data Entry keys 2 and 4 would remove Programs 2 and 4 from the
Pump configuration.
6.5 STACK OR NO STACK
The Stack/No Stack feature allows you to run your programs one after another (Stack) or
simultaneously (No Stack). If the volume of water and the pressure will allow, you have the option
of running several stations from different programs at the same time.
NOTE:
The maximum current draw cannot exceed 1 ampere per station and 1.5
amperes
for
the
controller.
EXAMPLE:
You have a 30 station controller, and watering must be completed by 7:00 AM and
cannot begin until 2:00 AM (5 hours total).
You would configure the Programs as follows:
Stations 1 through 7 in Program Number 1
Stations 8 through 14 in Program Number 2
Stations 15 through 21 in Program Number 3
Stations 22 through 30 in Program Number 4
Set the runtimes for each station, and the start time of 2:00 AM, you must be sure not to have any
program run over 5 hours total (total runtime can be checked using the REVIEW feature). You must
also ensure that your system can provide the volume of water required to supply 4 stations at one
time.
EXAMPLE:
To activate the No Stack feature,
Continue
to
Press:
Until display indicates:
2
MON
4
WED
ENTER
PUMP 24
PROGRAM
SETUP
STACK
PROGRAM
Содержание RME EAGLE