Cables
and
connectors
•
Cable
ties
•
Sealing
material
•
Waterproofing
tape
such
as
Scotch
23
Tape
¾”
wide,
from
3M
to
ensure
IP
‐
67
compliant
protection
against
water
and
dust
Cables
and
connectors
•
ODU
grounding
cable
10
AWG
•
ODU
‐
PoE
cable
(outdoor
class,
CAT
‐
5e,
4
twisted
pairs,
24AWG):
•
Up
to
100
m.
for
100BaseT
connection.
•
For
a
1000BaseT
connection
(HBS
only)
use
an
ODU
‐
PoE
cable
no
longer
than
75m.
•
External
CAT
‐
5e
cable
diameter
should
be
between
7
‐
9
mm
to
ensure
waterproof
sealing.
Safety
Practices
and
Provisions
Preventing
Overexposure
to
RF
Energy
To
protect
against
overexposure
to
RF
energy,
install
the
ODUs
so
as
to
provide
and
maintain
minimal
separation
distances
from
all
persons.
When
the
system
is
operational,
avoid
standing
directly
in
front
of
the
antenna.
Strong
RF
fields
are
present
when
the
transmitter
is
on.
The
ODU
must
not
be
deployed
in
a
location
where
it
is
possible
for
people
to
stand
or
walk
inadvertently
in
front
of
the
antenna.
Grounding
All
RADWIN
products
should
be
grounded
during
operation.
In
addition:
•
All
ODUs
should
be
earthed
by
a
wire
with
diameter
of
at
least
10
AWG
.
RADWIN
5000
HPMP
ODUs
must
be
properly
grounded
to
protect
against
lightning.
It
is
the
user's
responsibility
to
install
the
equipment
in
accordance
with
Section
810
of
the
National
Electric
Code,
ANSI/NFPA
No.70
‐
1984
or
Section
54
of
the
Canadian
Electrical
Code.
These
codes
describe
correct
installation
procedures
for
grounding
outdoor
units,
masts,
lead
‐
in
wiring
and
discharge
units.
It
also
lays
down
the
size
of
grounding
conductors
and
connection
requirements
for
grounding
electrodes.
RADWIN
5000
HPMP
ODUs
must
be
grounded
to
a
Protective
Earth
in
accordance
with
the
Local
Electrical
Regulations.
Note
For
1000BaseT,
you
should
use
RADWIN
supplied
ODU
‐
PoE
cables,
which
guarantees
1Gb
performance.
RADWIN
cannot
guarantee
1Gb
performance
if
you
use
third
party
cables.
Содержание 5000 HPMP
Страница 1: ...USER MANUAL RADWIN 5000 POINT TO MULTIPOINT BROADBAND WIRELESS Release 3 5 70...
Страница 21: ...Part 1 Basic Installation Release 3 5 70...
Страница 69: ...Part 2 Sector Installation Release 3 5 70...
Страница 155: ...Part 3 Sector Management Release 3 5 70...
Страница 191: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 36 Inventory Inventory You should note the details for each HSU...
Страница 193: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 38 Date Time Date Time The functionality is identical as that for the HBS...
Страница 197: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 42 Nomadic...
Страница 252: ...RADWIN 5000 HPMP User Manual Release 3 5 70 11 8 Registering HMUs 3 Open the Air Interface tab...
Страница 290: ...Part 4 Site Synchronization Release 3 5 70...
Страница 319: ...RADWIN 5000 HPMP User Manual Release 3 5 70 16 7 Configuring the GSU...
Страница 320: ...Part 5 Advanced Installation Topics Release 3 5 70...
Страница 354: ...Part 6 Field Installation Topics Release 3 5 70...
Страница 387: ...RADWIN 5000 HPMP User Manual Release 3 5 70 25 12 Configure If you change any of these fields you will cause a HBS reset...
Страница 395: ...RADWIN 5000 HPMP User Manual Release 3 5 70 25 20 WEB Interface for VMUs The current position is marked with the icon...
Страница 396: ...Part 7 Product Reference Release 3 5 70...
Страница 510: ...RADWIN 5000 HPMP User Manual Release 3 5 70 F 5 Montage sur un mur Montage sur un mur Figure F 5 Montage sur un mur...
Страница 517: ......