RADWIN
5000
HPMP
User
Manual
Release
3.5.70
15
‐
1
Chapter
15:
Hub
Site
Synchronization
over
Ethernet
RADWIN
Ethernet
HSS
Ethernet
HSS
Requirements
The
RADWIN
Ethernet
Hub
Site
Synchronization
(HSSoE)
method
provides
intra
‐
site
synchronization
without
the
need
for
external
cables
or
an
HSS
unit.
Sync
signals
are
exchanged
between
collocated
radios
over
the
regular
Ethernet
connection.
The
Ethernet
HSS
(HSSoE)
method
requires
Layer
2
Ethernet
connectivity
between
collocated
ODUs.
It
has
two
requirements:
•
Collocated
ODUs
providing
Ethernet
services
only,
should
be
connected
to
an
IDU
‐
H
instead
of
regular
PoE
devices.
Other
simple
switches
may
work
with
degraded
per
‐
formance.
They
are
not
recommended
and
problems
arising
from
their
use
will
not
be
eligible
for
any
kind
of
support.
•
Collocated
RADWIN
2000
class
ODUs
providing
E1/T1
services
should
use
an
IDU
‐
C
or
IDU
‐
E
and
then
be
connected
to
an
IDU
‐
H
functioning
as
a
switch.
One
of
the
LAN
ports
on
the
IDU
‐
C
or
IDU
‐
E
is
connected
to
any
of
the
six
IDU
‐
H
PoE
ports
or
the
two
LAN
ports.
(This
is
possible
because
the
IDU
‐
C
or
IDU
‐
E
LAN
cable
only
uses
four
pins
for
data;
the
power
pins
are
not
used
so
there
is
no
risk
of
damage
to
them.)
In
this
way,
up
to
eight
such
ODUs
may
be
collocated.
Note
You
may
only
use
one
IDU
‐
H.
That
is,
they
may
not
be
cascaded.
Caution
If
you
are
using
an
IDU
‐
C0
(GbE)
it
must
be
connected
to
the
IDU
‐
H
LAN
port
only.
Connecting
it
to
the
P0E
ports
will
damage
the
unit
and
in
any
event,
it
will
not
work.
Содержание 5000 HPMP
Страница 1: ...USER MANUAL RADWIN 5000 POINT TO MULTIPOINT BROADBAND WIRELESS Release 3 5 70...
Страница 21: ...Part 1 Basic Installation Release 3 5 70...
Страница 69: ...Part 2 Sector Installation Release 3 5 70...
Страница 155: ...Part 3 Sector Management Release 3 5 70...
Страница 191: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 36 Inventory Inventory You should note the details for each HSU...
Страница 193: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 38 Date Time Date Time The functionality is identical as that for the HBS...
Страница 197: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 42 Nomadic...
Страница 252: ...RADWIN 5000 HPMP User Manual Release 3 5 70 11 8 Registering HMUs 3 Open the Air Interface tab...
Страница 290: ...Part 4 Site Synchronization Release 3 5 70...
Страница 319: ...RADWIN 5000 HPMP User Manual Release 3 5 70 16 7 Configuring the GSU...
Страница 320: ...Part 5 Advanced Installation Topics Release 3 5 70...
Страница 354: ...Part 6 Field Installation Topics Release 3 5 70...
Страница 387: ...RADWIN 5000 HPMP User Manual Release 3 5 70 25 12 Configure If you change any of these fields you will cause a HBS reset...
Страница 395: ...RADWIN 5000 HPMP User Manual Release 3 5 70 25 20 WEB Interface for VMUs The current position is marked with the icon...
Страница 396: ...Part 7 Product Reference Release 3 5 70...
Страница 510: ...RADWIN 5000 HPMP User Manual Release 3 5 70 F 5 Montage sur un mur Montage sur un mur Figure F 5 Montage sur un mur...
Страница 517: ......