RADWAG PUE HX7 Скачать руководство пользователя страница 5

 

 

1.  INTENDED USE 

 

PUE  HX7  weighing  indicator  is  a  device  intended  to  make  industrial  scales 

operating on the basis of load cells. It is equipped with a stainless steel housing 

of  high  IP.  The  PUE  HX7  features  7’’  colour  display  guaranteeing  perfect 

readability,  and  a  diode  bar  graph  visualising  MIN,  MAX  thresholds.  It  is 

operated  using  22-key  membrane  keypad  equipped  with  programmable 

function keys. 

 

PUE  HX7  indicator  of  standard  design  offers  RS232,  USB  type  A,  Ethernet,  

4  I/O  interfaces.  Optionally  it  can  be  equipped  with  an  internal  battery,  this 

allows  its  operation  in  places  where  there  is  no  access  to  the  mains.  

The device integrates with receipt and label printers, barcode scanners and PC 

accessories (mouse, keyboard, USB flash drive). 

 

 

2.  WARRANTY CONDITIONS 

 

A.  RADWAG feels obliged to repair or exchange all elements that appear  

to be faulty by production or by construction.  

B.  Defining defects of unclear origin and means of their elimination can only 

be  realized  with  the  assistance  of  the  manufacturer  and  the  user 

representatives. 

C.  RADWAG  does  not  bear  any  responsibility  for  damage  or  losses 

resulting  from  unauthorized  or  inadequate  performing  of  production  

or service processes. 

D.  The warranty does not cover: 

  mechanical  damage  caused  by  product  exploitation  other  than 

intended, damage of thermal and chemical origin, damage caused by 

lightning, overvoltage in the power network or other random event, 

  inappropriate cleaning habits. 

E.  Loss of warranty takes place if: 

  a repair is carried out outside RADWAG authorized service point, 

  service claims intrusion into mechanical or electronic construction by 

unauthorized people, 

  the scale does not bear security seal stickers. 

F.  Warranty  conditions  outline  the  warranty  period  for  rechargeable 

batteries attached to the device for 12 months. 

G.  For detailed warranty conditions read the warranty certificate.  

H.  Contact with the central authorized service: +48 (48) 386 63 30. 

Содержание PUE HX7

Страница 1: ......

Страница 2: ...2 JULY 2020...

Страница 3: ...mage immediately unplug the device from the mains Scales to be decommissioned must be decommissioned in accordance with valid legal regulations Do not let battery discharge in case of prolonged storag...

Страница 4: ...t 17 7 3 1 Numerical Box 17 7 3 2 Text Box 19 7 3 3 Diacritical Sign Table 20 7 3 4 Special Sign Table 21 7 4 Return to Weighing 21 8 INSTALLER INSTRUCTION 22 8 1 Connecting 6 Wire Load Cell 22 8 2 Co...

Страница 5: ...by construction B Defining defects of unclear origin and means of their elimination can only be realized with the assistance of the manufacturer and the user representatives C RADWAG does not bear an...

Страница 6: ...ing routine removal of small stains 1 Remove the dirt using cloth dipped in warm water 2 For best results add a little bit of dishwashing detergent 3 2 Cleaning ABS Components To clean dry surfaces an...

Страница 7: ...7 4 MECHANICAL DESIGN 4 1 Dimensions PUE HX7 overall dimensions...

Страница 8: ...P connector option 7 RS485 M12 8P connector option 8 Cable gland for a cable of a weighing platform 1 9 Cable gland for a cable of a weighing platform 2 option 10 ETHERNET RJ45 connector 11 USB connec...

Страница 9: ...in5 GND Pin6 GND Pin7 24VDC Pin8 24VDC 4INPUTS Pin1 OUT1 Pin2 OUT2 Pin3 WY3 Pin4 OUT4 Pin5 COM Pin6 24VDC Pin7 GND Pin8 NC 4OUTPUTS Pin1 IN1 Pin2 IN2 Pin3 IN3 Pin4 IN4 Pin5 COM Pin6 24VDC Pin7 GND Pin...

Страница 10: ...in5 COM Pin6 24VDC Pin7 GND Pin8 NC 4INPUTS Pin1 IN1 Pin2 IN2 Pin3 IN3 Pin4 IN4 Pin5 COM Pin6 24VDC Pin7 GND Pin8 NC 4 4 1 Technical Specifications Output parameters Output quantity 4 Output type Soli...

Страница 11: ...4 4 2 I O Schematic Diagrams 4 inputs 4 outputs 4 5 Operation Panel Keys Press to switch the device on off Press to enter the main menu Press to log in Press to cancel the message Press to zero the sc...

Страница 12: ...n screen button Programmable key assigned to an on screen button Programmable key assigned to an on screen button 4 6 Technical Specification Housing Stainless steel IP rating IP68 IP69 Display 7 colo...

Страница 13: ...he air bubble takes central position 5 2 Start Up Plug the power cord to the mains Press key it is to be found at the top of the operation panel Upon completed start up the home screen is displayed au...

Страница 14: ...y the following message Excessively discharged battery Scale shutdown is to occur Upon scale shutdown connect it to the mains in order to charge the battery 6 HOME SCREEN The home screen features 4 se...

Страница 15: ...lt window provides all weighing related data 6 3 Workspace The workspace is to be found underneath the weighing result window The workspace comprises 4 programmable widgets Each working mode features...

Страница 16: ...that operate as arrow keys Menu view 7 2 Menu Keys Press to enter the main menu Press to go to the home screen Press to go back or to discard entering parameter modifications Press to go back Press to...

Страница 17: ...e it by one digit down 7 3 Entering Numbers Text The software features two different edit boxes numerical box for entering part mass values tare values etc text box for entering printout template univ...

Страница 18: ...r a few seconds long press Press to enter digit 6 Press to enter digit 7 Press to enter digit 8 Press to enter digit 9 Press to enter digit 0 Press to enter dot hold the key for a few seconds long pre...

Страница 19: ...case character mode digit mode arrow keys operation bottom bar operation Press to save the project to lb file on a USB flash drive Press to read the project saved to lb file on a USB flash drive Pres...

Страница 20: ...move the cursor down long press Press to enter w x y z Press to activate Caps Lock function long press Press to enter space sign Press to enter sign dot long press Press to go to the next line in the...

Страница 21: ...ate special signs table while editing text box it is necessary to press and hold key Where Function inactive Press to switch to diacritical sign keyboard 7 4 Return to Weighing Introduced modification...

Страница 22: ...scales 8 1 Connecting 6 Wire Load Cell Connect 6 wire load cell to the main board following the diagram below 6 wire load cell connection Load cell junction J14 Load cell signals NOTES REF SENSE JP6 n...

Страница 23: ...d cell signals Notes REF JP6 soldered REF JP5 soldered IN OUTPUT IN OUTPUT 5V INPUT AGND INPUT 8 3 Connecting Load Cell s Cable Shield To ensure correct scale operation follow below instructions regar...

Страница 24: ...INT C Point C threaded pin galvanically connected with an indicator housing for fixing of a ring terminal E solder pad on DP4 module 9 FACTORY SETUP To access and modify factory settings and parameter...

Страница 25: ...a in a top bar of the home screen Scale name Special name and or name of RADWAG distributor s device 15 characters maximum Value entered here replaces the set Scale type value Platform quantity 1 1 2...

Страница 26: ...0 02 0 05 0 1 0 2 0 5 1 2 5 10 20 50 Verification units for Range 2 none value unverified version Digit marker None None 1 2 3 Setting quantity of digits counting from the last digit of the displayed...

Страница 27: ...instrument adjustment menu External adjustment Scale adjustment refer to section 9 6 1 Start Mass Determination Start mass determination refer to section 9 6 2 Start mass 100 Current start mass expres...

Страница 28: ...5 Scale Defining Defining the device at the production stage requires entering basic scale parameters serial number weighing device type Procedure Enter Global Scale defining submenu message Continue...

Страница 29: ...justment Please wait is displayed Upon adjustment completion message Remove weight is displayed Unload the weighing pan the weighing device displays the Adjustment submenu The adjustment of additional...

Страница 30: ...isplayed window Upon result stabilization press key to confirm Mass edit box is displayed again second linearity correction point Linearity correction process for the 2nd point is analogous to the lin...

Страница 31: ...ates changes of gravity force being a result of different latitude It allows to carry out correct scale calibration adjustment away from the point of subsequent use The gravity correction value must b...

Страница 32: ...sing indicator menu For 12IN 12OUT module the indicator s housing cover features two cable glands through which 3 meter long leads terminated with strip wires are fed 10 1 1 Technical Specifications O...

Страница 33: ...nals Overview Signals transmitted via 16 x 0 5 mm2 cable with numbered wires INPUTS OUTPUTS Wire number Signal Wire number Signal 1 IN1 1 OUT1 2 IN2 2 OUT2 3 IN3 3 OUT3 4 IN4 4 OUT4 5 COMM1 5 COMM1 6...

Страница 34: ...utput module 10 2 1 AN Module Configuration The module s working mode is set using S1 switch when setting the module s working mode refer to the below table Analog outputs module board provides descri...

Страница 35: ...30V DC max 40mA 10 2 3 AN Module Diagrams of Connection Cables Voltage output wiring diagram WIRE COLOURS Colour Signal pink UOUT grey GND yellow 24V DC green GND Current output wiring diagram WIRE C...

Страница 36: ...aximum load cell impedance 1200 Load cell power supply 5V Load cell wiring 4 or 6 wires shield Multi range option YES 10 3 2 Colours of Weighing Platform s Signal Wires Markings RADWAG Colour Marking...

Страница 37: ...5Rxxxx board ver A Position of PROFIBUS module on 385Rxxxx board ver A The indicator is equipped with input and output connectors On the output connector there is 5 VDC voltage this provides correct o...

Страница 38: ...38 11 DIAGRAMS OF CONNECTION CABLES Indicator computer cable Indicator printer cable ZEBRA Indicator printer cable EPSON...

Страница 39: ...39 Indicator IN OUT cable Indicator barcode scanner cable LS2208 Indicator PRINT TARE ZERO STOP cable Scale Ethernet cable is a standard network cable terminated with RJ45 connectors on both ends...

Страница 40: ...40 12 ERROR MESSAGES...

Страница 41: ...41...