Performing Initial Configuration of the SCOPIA Elite MCU | 18
RADVISION | Installation Guide for SCOPIA Elite 5200 Series MCU Version 7.5
Procedure
Step 1
Connect the serial cable from the PC terminal to the serial port on the front panel of the upper
Media Blade.
Step 2
Connect the power cable.
Step 3
Start the terminal emulation application on the PC.
Step 4
Set the communication settings in the terminal emulation application on the PC as follows:
•
Baud rate: 9600
•
Data bits: 8
•
Parity: None
•
Stop bits: 1
•
Flow control: None
Step 5
Turn on the power to the MCU.
A log of the auto-boot events scrolls across the computer monitor.
Step 6
When the message “Press any key to start configuration” appears on the screen, press any key
within 10 seconds.
The network configuration Main menu appears:
Main menu
N: Configure network port values
P: Change the configuration software password
S: Configure network security mode
T: Configure TFTP servers list
A: Advanced configuration menu
Q: Quit
Note:
If you do not press a key before the countdown ends, the device continues its initialization
and you will need to reboot the device to return to the network configuration Main menu.
Step 7
Enter N at the prompt to configure default network port values and press Enter.
Step 8
Enter 2 to change the network configuration.
Step 9
Enter N at the prompt to enable IPv6 in addition to IPv4.
Step 10
Enter N at the prompt to enable IP separation.
Step 11
Enter the IP address you want to assign to the MCU at the Management IP address prompt and
press Enter.
Note:
Do not use leading zeros in the IP address and ensure both IP addresses must be on the
same subnet.