1. INSTALLATION
INST
ALLER
REMOTE STORAGE SYSTEM - CONNECTION OF STORAGE TANK PROBE AND DIVERTER VALVE
Carry out the following electrical wiring onto the MASTER board: M9 terminal block storage tank probe:
insert the storage tank probe cable inside the panel inserting the terminals 35 and 34. It is not necessary
to follow an order of the wires.
- M4 terminal block - diverter valve: connect the motor cable of the diverter valve by means of the molex
clamp. Insert the cable inside the panel and connect the terminals of the cable to the terminal block M4
paying attention to the combinations: blue – terminal no. 9; brown – terminal no. 8; black – terminal no.
10. Once the wiring has been completed, the value of parameter P32 must be set to ‘0’.