2. FIRST START-UP
SER
VICE
CENTRE
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P02
GAS TYPE SELECTION
ATTENTION:
READ THE INSTRUCTION IN CHAPTER ‘GAS
CONVERSION’ BEFORE CHANGING THIS
PARAMETER.
0 - 1
0 = NATURAL GAS
1 = GPL
P03
SETTING THE HEATING TEMPERATURE
IN CASE OF DIRECT SUPPLY, BY A BOILER, OF
A LOW TEMPERATURE SYSTEM, INSTALL A
SECURITY THERMOSTAT ON THE DELIVERY WHICH
INTERRUPTS THE OPERATION OF THE BOILER
IN CASE OF HIGH DELIVERY TEMPERATURE. THE
COMPANY IS NOT HELD LIABLE FOR RESULTING
DAMAGES TO PERSONS OR THINGS DUE TO THE
NON-OBSERVANCE OF SUCH INDICATION.
0 - 1
0 = STANDARD (30-80 °C)
(SET BY DEFAULT)
1 = REDUCED (25-45 °C) FOR
FLOOR SYSTEMS
P04
HEATING RUN-UP
THROUGH THIS PARAMETER YOU CAN SET THE
TIME, DURING START-UP PHASE, NECESSARY FOR
THE BOILER TO REACH THE MAXIMUM SET POWER
(IN HEATING).
0 - 5
0 = (DISABLED)
1 = 50 SECONDS
2 = 100 SECONDS
3 = 200 SECONDS (SET BY
DEFAULT)
4 = 400 SECONDS
5 = 600 SECONDS
P05
TIME DURING THE PRIMARY START-UP OF A SINGLE
UNIT
BY MEANS OF THIS PARAMETER, IT IS POSSIBLE
TO SET THE TIME DURING WHICH A SINGLE UNIT
BECOMES PRIMARY DURING THE START-UP, AFTER
WHICH THE AUTOMATIC REVERSAL WITH THE
OTHER UNIT OCCURS.
0 - 255
THE VALUE IS EXPRESSED IN
HOURS
(PRE-SET TO 50 HOURS)
P06
TURN OFF OF A SINGLE UNIT
1 - 3
1 = START ONLY MASTER
2 = START ONLY SLAVE
3 = BOTH TURNED ON