1. INSTALLATION
INST
ALLER
To wire the optional items below:
• (TP) D.H.W PRE-HEATING DEACTIVATION TIMER
• BUS 0-10V
• (SVZ) ZONE VALVES MANAGEMENT KIT
CONNECTED TO A REMOTE CONTROL COD. 65-
00030
• (AG) GENERIC DEVICE. MAXIMUM CURRENT
3A WITH 250VAC (SEE RELAY MANAGEMENT AT
PARAMETER P69)
• (CSF) FLOW SWITCH SAFETY CONTACT (SEE
PARAMETER P72)
operate on the P.C.B. placed inside the GREY
control panel as follows:
DANGER
Cut off the voltage from the main switch.
› remove the boiler front casing (refer to chapter
ACCESSING THE BOILER).
› remove the control panel back plate (see chapter
ACCESSING THE P.C.B.).
› after removing the back plate, connect the items
below to the P.C.B. (see fig. 1).
After performing these operations, remount the
back plate and the front casing.
TP
BUS 0-10V
GND
BUS+
11
10
9
8
7
12
13
14
15
16
17
M12
M9
M7
M5
M2
M4
M8
M10
M15
M16
1
2
3
4
57
61
60
59
58
44 43 42 41 40 39 38
37 36 35 34 33 32
31 30 29 28
27 26
MIAH4
62
63
64
65
66
67
68
51
52
53
54
55
56
5
6
M13
M14
ar
ar
ne
ne
ce
ma
COD.40-00133
220 V - 50 Hz
L
N
VZR
VZ2
VZ1
FC
FC
TAZ 2
TAZ 1
AG
1
2
3
4
5
6
9 8 7
M1
M4
M2
M3
SVZ
L
gr
ar
ro
ne
N
RA
CSF(*)
PA
fig. 1
(*) :
TO BE CONNECTED ONLY TO THE SLAVE PANEL
FC:
ZONE VALVES LIMIT SWITCH
TAZ1:
ROOM THERMOSTAT ZONE 1
GR:
GREY
TAZ 2:
ROOM THERMOSTAT ZONE 2
AR:
ORANGE
VZ1:
ZONE VALVE 1
NE:
BLACK
VZ2:
ZONE VALVE 2
MA:
BROWN
VZR:
REMOTE CONTROLLED ZONE VALVE
CE:
BLUE
RA: AUXILIARY
RELAY
RO: RED