1. INSTALLATION
INST
ALLER
ATTENTION
By using a flue manifold kit for this boiler
model, the installation of the non-return flue damper
(1 - fig. 1, code: 50-00452), included as a standard
equipment inside the boiler’s package, is required.
IN ORDER TO INSTALL THE NON-RETURN FLUE
DAMPER IN THE FLUE MANIFOLD KIT Ø100,
PLEASE PROCEED AS FOLLOWS:
1. Install the non-return flue damper ‘1’ (fig. 1)
in the flue vertical adapter ‘2’, using the forced
couplings ‘A’ and ‘B’ and pushing it until it sits into
place.
2. Insert the flue vertical adapter ‘3’ in the manifold
connection adapter until it sits into place, using the
forced ‘D’ and ‘E’ couplings.
3. Tighten the flue vertical adapter ring-nut ‘3’ on
the manifold connection adapter.
4. Insert the flanged vertical adapter ‘5’ on the flue
vertical adapter ‘3’.
5. Repeat the installation described from point 1
to point 4 for the other flue manifold connection
adapter.
6. Fasten using some screws the ‘5’ flanged
vertical adapters on the top of the boiler.
A
B
1
2
E
5
4
3
D
E
5
3
D
4
fig. 1