1. INSTALLATION
INST
ALLER
1.1.17. GAS CONNECTION
DANGER
In order to connect the boiler gas
connector to the supply pipe, use a stop seal of an
appropriate size and material. The use of hemp,
teflon tape or similar materials is strictly forbidden.
BEFORE PERFORMING THE GAS CONNECTION,
MAKE SURE THAT:
› the gas supply line complies with the standards
and regulations in force;
› the piping section suits the requested capacity
and its length;
› the piping is equipped with all safety and control
devices required by the standards in force;
› the internal and external seals of the gas inlet
system are checked;
› the boiler is suitable for use with the available
type of gas by checking the boiler data plate
(placed on the inner side of the front casing. If
they do not match, please take the necessary
measures to adapt the boiler to another type of
gas (see chapter GAS CONVERSION);
› the gas supply pressure falls within the values
indicated on the data plate.
1.1.18. ELECTRICAL CONNECTION
DANGER
The boiler is electrically safe only if it is
properly connected to an efficient earthing system,
performed in compliance with the safety standards
in force. Check this essential safety requirement is
strictly recommended. If in doubt, request an accurate
check of the electrical system performed by qualified
staff, as the manufacturer is not responsible for any
damages caused by lack of earthing system.
› Make sure that the electrical systems is suitable
for the maximum power absorbed by the boiler,
value indicated on the data plate.
› make sure that the cables section is appropriate
for the maximum power absorbed by the boiler
and that it is however not lower than 1 mm
2
.
› The equipment works with alternating current
of 230 V and 50 Hz. The electrical connection
must be performed using an all-pole switch with
an opening of at least 3 millimetres between
contacts placed upstream from the device.
WARNING
Make sure that the live and neutral cables
connection is performed in compliance with the
wiring diagram (see chapter POWER SUPPLY).
WARNING
It is strictly forbidden the use of adaptors,
multiple plugs and/or extensions for the general
power supply of the boiler from the electrical network.