IQ3 Street Logger Dash Installation Manual
26
Setting as
Displayed on
Dash
Program
Setting Description
Programming
Command
Accept and
Advance
Accept and
Exit
WARN -
OIL PRESS
Low oil pressure warning value
Value to be used for control of
Low oil pressure Light
Factory Default is 20
Short Press Button 2
Increases by 1
Medium Press
Button 2
Decreases by 10
Short Press
Button 1
Long Press
Button 1
FAN ON TEMP
Fan On Output value
Value to be used for control for fan
output
Factory Default is 180
Short Press Button 2
Increases by 1
Medium Press
Button 2
Decreases by 10
Short Press
Button 1
Long Press
Button 1
FAN OFF TEMP
Fan Off Output value
Value to be used for control for fan
output
Factory Default is 175
Short Press Button 2
Increases by 1
Medium Press
Button 2
Decreases by 10
Short Press
Button 1
Long Press
Button 1
Entering Setup 2
1.
Press and hold Button 2 for TWO shift light blinks – MEDIUM press
2.
The Dash will display SETUP 2?
3.
Confirm by pressing Button 1 for ONE shift light blink – SHORT press
To cancel entering Setup Mode 2, press Button 2 for SHORT press
Setting as
Displayed on
Dash
Program Setting Description
Programming
Command
Accept and
Advance
Accept and
Exit
CALIBRATE
SPEED
Calibrates dash speed settings
N = No
Y = Yes
See Speedometer Calibration section
for detailed instructions
Short Press Button 2 to
toggle between Y/N
Short Press
Button 1
Long Press
Button 1
CALIBRATE
GEARS
Calibrates Gear Position Indicator for
each gear.
Manual transmissions only
N = No
Y = Yes
See Gear Position Calibration section
for detailed instructions
Short Press Button 2 to
toggle between Y/N
Short Press
Button 1
Long Press
Button 1
Содержание 250-DS-IQ3SL