IQ3 Street Logger Dash Installation Manual
16
18
Cooling Fan
Violet/White
RELAY REQUIRED
(Do Not Connect to Fan Directly)
Optional, if a cooling fan control is desired.
Connect to the negative side of cooling fan relay; typically pin
86 on a standard automotive relay.
This output controls ground to the circuit when cooling fan
on/off value is met.
750mA ground sink maximum
See the Cooling Fan Wiring Diagram below
19
Not Used
N/A
20
Not Used
N/A
21
Fuel Level
Blue
Connect to the fuel sender output signal.
22
Not Used
N/A
23
Not Used
N/A
24
Not Used
N/A
25
CAN Low
Green
CAN Low for ECU connections if applicable
26
Battery Ground
Black
Connect this input to a battery ground
27
Not Used
N/A
28
Not Used
N/A
29
Remote Switch 2
Gray/White
Connect to a normally open momentary pushbutton.
Momentarily grounding this input will activate button 2
circuit. See button functions later in this manual for
complete description of all button functions
30
Remote Switch 1
Brown/White
Connect to a normally open momentary pushbutton.
Momentarily grounding this input will activate button 1
circuit. See button functions later in this manual for
complete description of all button functions