TEX1002LCD
17
/ 26
User Manual
Rev. 1.0 - 22/08/14
To edit an item, highlight the appropriate line using the and buttons and
then press and hold the
ENTER
button until the command is accepted. This way,
Pwr setting is toggled between On and Off and Mod setting is toggled between
“x1” and “x10”. To edit the Power Good rate, simply select item “PgD” or “PgR” and
edit its value using the UP and DOWN buttons; finally, press
ENTER
to confirm.
Menu 4
Pwr
Enables (ON) or disables (OFF) transmitter power output.
Mod
Modifies modulation display (toggles between “x1” and “x10”). In “x10”
mode, instantaneous deviation indication is multiplied by a factor of 10,
and the bar meter on the default menu will reflect 7.5 kHz instead of
75 kHz. This display mode is convenient when you wish to display low
deviation levels, such as those caused by pilot tone or subcarriers.
PgD
Modifies Power Good threshold for forward power. The Power Good
rate is a percent of equipment rated power (1000W for
TEX1002LCD
),
not of forward output power. This means that this threshold set at 50%
will give 500 W, respectively, regardless of set power level. The Power
Good feature enables output power control and reporting. When output
power drops below set Power Good threshold, the equipment changes
the state of pin [7] of the DB15 “Remote” connector located on the rear
panel.
PgR
Modifies Power Good threshold for reflected power. The Power Good
rate is a percent of equipment rated power (100W for
TEX1002LCD
),
not of reflected output power. This means that this threshold set at 5%,
respectively, will give 5W regardless of set power level. The Power Good
feature enables output power control and alarm management.
NOTE: This alarm does not trip any contacts in the DB15 “Remote” connector and
is only available in systems equipped with telemetry.