11
E
N
G
L
I
S
H
2
1
3
4
5
6
11 - ELECTRICAL SETUP
Electrical setup - Internal view
1.
Function selector (shielded cable 8 x Ø 0.22 mm)
2.
Possible push button control (cable 2 x Ø 0.22mm)
3.
Control by key or external code (cable 4 x Ø 0.22mm)
4.
Power supply cable(Neutral, Line, Earth) (cable 3 x Ø 1.5 mm)
5.
Safety photocells (cable provided to be run all the way into the beam)
6.
Impulse parts (radar) (cable 4 x Ø 0.22 mm)
Looking at the box of the automation, all cables must arrive at the right side with 3 m. of excess
cable.
N.B.
If you use a single pair of photocells, the
height of fastening above the ground is
50 cm.
If you use a double pair of photocells, the
height of fastening above the ground is 20
and
100
cm.
External view - double pair of photocells
Содержание WINNY LIGHT
Страница 5: ...5 E N G L I S H 4 SPACE REQUIRED VERTICAL SECTION ...
Страница 6: ...6 VERTICAL SECTION WITH CRASH BAR ...
Страница 7: ...7 E N G L I S H VERTICAL SECTION WITH COMMERCIAL PROFILES COMMERCIAL PROFILE COMMERCIAL PROFILE ...
Страница 27: ...27 E N G L I S H ...
Страница 28: ......
Страница 29: ...I T A L I A N O manuale d u s o e m a n u t e n z i o n e AUTOMAZIONE PER PORTE SCORREVOLI Winny ...
Страница 33: ...5 I T A L I A N O 4 SPAZI RICHIESTI ...
Страница 34: ...6 ...
Страница 35: ...7 I T A L I A N O ...
Страница 55: ...27 I T A L I A N O ...