4
2 - TECHNICAL FEATURES
Technical information
Primary power supply
230 V AC 50 Hz
Fuse 5 A
Note
A bi-polar switch must be installed near the motorized
crosspiece. This is to be the service switch that cuts off
the power supply for all routine maintenance.
Consumption
max.
120
W
Electric lock
12 V DC Const. v. 6 V DC with Pid Control
Battery charger
Charging voltage 27.5 V DC I max =0.5 A with
control in current
Electrical motor
24 V DC max power 80 VA
Protection
fuse
10
A.T.
Performance
Maximum recommended weight
1 door 160 Kg
per door
2 doors 130 Kg + 130 Kg
Opening closing speed
individually adjustable
Opening pause time
adjustable from 0 to 90 seconds
Operating temperature
from – 10°C to +80°C
The automation is suitable for indoor installation with heavy use, or outdoors provided it is
protected from the elements.
3 - TOOLS FOR ASSEMBLY
Dynamometric wrench
3-15 Nm
Allen
wrench
4mm,
5mm
Wrench 8mm,
10mm
Set of bits, drill, electric screwdriver
Screwdrivers
Phillips
(small, large), flathead (small)
Function
programmer
Electrician's
scissors
Содержание WINNY LIGHT
Страница 5: ...5 E N G L I S H 4 SPACE REQUIRED VERTICAL SECTION ...
Страница 6: ...6 VERTICAL SECTION WITH CRASH BAR ...
Страница 7: ...7 E N G L I S H VERTICAL SECTION WITH COMMERCIAL PROFILES COMMERCIAL PROFILE COMMERCIAL PROFILE ...
Страница 27: ...27 E N G L I S H ...
Страница 28: ......
Страница 29: ...I T A L I A N O manuale d u s o e m a n u t e n z i o n e AUTOMAZIONE PER PORTE SCORREVOLI Winny ...
Страница 33: ...5 I T A L I A N O 4 SPAZI RICHIESTI ...
Страница 34: ...6 ...
Страница 35: ...7 I T A L I A N O ...
Страница 55: ...27 I T A L I A N O ...