M50 Hardware Design
M50_HD_V2.0
- 78 -
EGSM 900
@power level #5 <660mA,Typical 560mA
@power level #12,Typical 215mA
@power level #19,Typical 114mA
DCS 1800
@power level #0 <530mA,Typical 420mA
@power level #7,Typical 173mA
@power level #15,Typical 97mA
PCS 1900
@power level #0 <530mA,Typical 470mA
@power level #7,Typical 192mA
@power level #15,Typical 101mA
Note: GPRS Class 12 is the default setting. The module can be configured from GPRS Class 1
to Class 12 by “AT+QGPCLASS”. Setting to lower GPRS class would make it easier to design
the power supply for the module.
5.5. Electro-static discharge
Although the GSM engine is generally protected against Electrostatic Discharge (ESD), ESD
protection precautions should still be emphasized. Proper ESD handling and packaging procedures
must be applied throughout the processing, handling and operation of any applications using the
module.
The measured ESD values of module are shown in the following table.
Table 38: The ESD endurance (Temperature:25
℃
,Humidity:45 %)
Tested point
Contact
discharge
Air discharge
VBAT,GND
±5KV
±10KV
RF_ANT
±5KV
±10KV
PWRKEY
STATUS
±2KV
±4KV
SIM_VDD, SIM_DATA
SIM_CLK, SIM_RST
±2KV
±4KV
TXD, RXD
RTS, CTS, DTR
±2KV
±4KV
Others
±0.5KV
±1KV
Quecctel
Confidential