M50 Hardware Design
M50_HD_V2.0
- 35 -
STATUS pin, which is a low level voltage in this mode.
3.4.2.2. Power down module using AT command
Customer’s application can turn off the module via AT command “AT+QPOWD=1”. This
command will let the module to log off from the network and allow the firmware to save
important data before completely disconnecting the power supply, thus it is a safe way.
Before the completion of the power down procedure the module sends out the result code shown
below:
NORMAL POWER DOWN
After that moment, no further AT commands can be executed. And then the module enters the
power down mode, only the RTC is still active. The power down mode can also be indicated by
STATUS pin, which is a low level voltage in this mode.
Please refer to the
document [1]
for details about the AT command “AT+QPOWD”.
3.4.2.3. Over-voltage or under-voltage automatic shutdown
The module will constantly monitor the voltage applied on the VBAT, if the voltage is
≤
3.5V,
the following URC will be presented:
UNDER_VOLTAGE WARNING
If the voltage is
≥
4.5V, the following URC will be presented:
OVER_VOLTAGE WARNING
The normal input voltage range is from 3.3V to 4.6V. If the voltage is > 4.6V or < 3.3V, the
module would automatically shutdown itself.
If the voltage is < 3.3V, the following URC will be presented:
UNDER_VOLTAGE POWER DOWN
If the voltage is > 4.6V, the following URC will be presented:
OVER_VOLTAGE POWER DOWN
Note: These result codes do not appear when autobauding is active and DTE and DCE are not