M50 Hardware Design
M50_HD_V2.0
- 37 -
least 500ms should be delayed after detecting the low level of STATUS. The restart timing is
illustrated as the following figure.
PWRKEY
(INPUT)
STATUS
(OUTPUT)
Delay >0.5s
Turn off
Restart
Pull down the PWRKEY
to turn on the module
Figure 12:
Timing of restarting system
The module can also be restarted by the PWRKEY after emergency shutdown.
EMERG_OFF
(INPUT)
STATUS
(OUTPUT)
Delay >2s
6us
Pulldown >20ms
PWRKEY
(INPUT)
Figure 13:
Timing of restarting system after emergency shutdown