42
Troubleshooting
•
For the position of these LEDs on an SNC 4501, see
Figure 14
on 43 and refer to
Table 3
on page
44.
If there is a non-fatal power supply problem, or if a problem is detected before shut down occurs, the
Fault
LED flashes. The Fault LED also flashes briefly during start up. For more information, refer to
Visually
Inspect LEDs
on page 41.
Figure 12
LEDs on the Front of the SNC 4500
Table 1
LEDs on the Front of the SNC 4500
LED
Appearance
Meaning
Ethernet speed LED
amber
speed is 1 Gb/sec
Ethernet speed LED
green
speed is 100 MB/sec
Ethernet speed LED
off
speed is 10 MB/sec, or no link
Ethernet BUSY LED
blinking
I/O activity
Fault LED
on, amber
unit is starting up
Fault LED
blinking
fatal fault imminent
Ready LED
green on
POST completed, unit ready
SCSI bus activity LED
blinking
I/O activity
SCSI bus activity LED
solid
heavy I/O activity
Power
green on
sufficient power to operate
Power
off
power is insufficient
Содержание SNC 4500
Страница 1: ...www adic com ADVANCED DIGITAL INFORMATION CORPORATION SNC 450xUser sGuide...
Страница 6: ...vi Contents...
Страница 20: ...14 Getting Started Figure 4 Scalar 100 with Four LTO 1 or SDLT Drives...
Страница 23: ...SNC 450x User s Guide 17 Figure 6 Scalar 100 with Four LTO 2 Drives...
Страница 30: ...24 Getting Started...
Страница 46: ...40 Using the SNC Manager Interface...
Страница 112: ...106 Removal and Replacement Procedures...
Страница 116: ...110 iSCSI Performance Tuning...
Страница 119: ...SNC 450x User s Guide 113 BSMI Notice...
Страница 120: ...114 Regulatory Notices...