SNC 450x User’s Guide
5
Serial Port
The RS-232 serial port is an RJ-11 connection used to connect this port to the serial port on a service
computer. The position of the RS-232 serial port on an SNC 4500 can be seen in
Figure 8
on page 19. The
position of the RS-232 serial port on an SNC 4501 is shown in
Figure 9
on page 19.
The serial port provides support for remote monitoring and management when you use a terminal session
to access the command line interface (CLI).
The serial port is configured at:
•
Baud rate: 115,200 bits per second
•
Data Bits: 8
•
Parity: None
•
Stop Bits: 1
•
Flow Control: None
•
Terminal type: ASCII
•
Echo: off
Operating Specifications
This section contains the physical, electrical, and environmental specifications for the SNC 4500 and SNC
4501.
SNC 4500 Dimensions
•
Depth: 33.02 cm (13 in.)
•
Height: 4.37 cm (1.72 in.)
•
Width: 48.26 cm (19 in.)
•
Weight: 4.53 kg (10 lbs.)
SNC 4501 Dimensions
•
Depth: 17.78 cm (7 in.)
•
Height: 7.62 cm (3 in.)
•
Width: 15.24 cm (6 in.)
•
Weight: 1.13 kg (2.5 lbs)
Operating Environment
The operating environment is as follows:
•
Operating temperature: 10° to 40°C (50° to 104°F) external
•
Blower and airflow: Be sure there is sufficient airflow to the rack or library.
Note
To configure the management port IP address, you must use either the serial
port or the library operator panel.
Содержание SNC 4500
Страница 1: ...www adic com ADVANCED DIGITAL INFORMATION CORPORATION SNC 450xUser sGuide...
Страница 6: ...vi Contents...
Страница 20: ...14 Getting Started Figure 4 Scalar 100 with Four LTO 1 or SDLT Drives...
Страница 23: ...SNC 450x User s Guide 17 Figure 6 Scalar 100 with Four LTO 2 Drives...
Страница 30: ...24 Getting Started...
Страница 46: ...40 Using the SNC Manager Interface...
Страница 112: ...106 Removal and Replacement Procedures...
Страница 116: ...110 iSCSI Performance Tuning...
Страница 119: ...SNC 450x User s Guide 113 BSMI Notice...
Страница 120: ...114 Regulatory Notices...