74
Management Port Command Reference
get SCSIPortWideTransfer [port number]
The
get SCSIPortWideTransfer
command specifies if wide SCSI transfers are negotiated for a specific
port. Refer to
set SCSIPortWideTransfer [port number] [status]
on page 96.This command must be followed
by
saveConfiguration restart
.
Ready.
get scsiportwidetransfer 0
Port 0 ScsiPortWideTransfer = enabled
Ready.
get SerialPortBaudRate
The
get SerialPortBaudRate
command displays the baud rate for the RS-232 serial port. Refer to
set
SerialPortBaudRate [rate]
on page 96.
Ready.
get serialportbaudrate
SerialPortBaudRate = 115200
Ready.
get SerialPortEcho
The
get SerialPortEcho
command shows whether or not repetition of keyboard input on the screen has
been enabled. Refer to
set SerialPortEcho [status]
on page 97.
Ready.
get serialportecho
SerialPortEcho = disabled
Ready.
get SNTP
The
get SNTP
commands reports if the SNC is set to contact a specified Network Time Protocol (NTP)
server. Refer to
set SNTPServer [IP address]
on page 97.
Ready.
get sntp
SNTP = disabled
Ready.
get SNTPServer
The
get SNTPServer
command displays the current NTP time server address. Refer to
set SNTPServer
[IP address]
on page 97.
CAUTION
Contact ATAC before using this command.
Port Number
Meaning
0 or 1
SCSI connection labeled SCSI port 0 or SCSI port 1
Baud Rate Output
2400
9600
19200
38400
57600
115200
Содержание SNC 4500
Страница 1: ...www adic com ADVANCED DIGITAL INFORMATION CORPORATION SNC 450xUser sGuide...
Страница 6: ...vi Contents...
Страница 20: ...14 Getting Started Figure 4 Scalar 100 with Four LTO 1 or SDLT Drives...
Страница 23: ...SNC 450x User s Guide 17 Figure 6 Scalar 100 with Four LTO 2 Drives...
Страница 30: ...24 Getting Started...
Страница 46: ...40 Using the SNC Manager Interface...
Страница 112: ...106 Removal and Replacement Procedures...
Страница 116: ...110 iSCSI Performance Tuning...
Страница 119: ...SNC 450x User s Guide 113 BSMI Notice...
Страница 120: ...114 Regulatory Notices...