SNC 450x User’s Guide
31
•
Ensure the SNC is mapped to iSCSI LUN 0.
•
Map the SCSI devices with sequential IDs starting at 0 for each device.
4
Click
Submit.
All the CLI commands necessary to enable mapping and the command
saveconfiguration
norestart
will be performed.
•
If devices are not properly displayed, open the SNC Manager
Advanced
page. In the
Enter a CLI
command
text box, enter the
SCSITargets
command to make sure all devices are online. Then
enter the
autoMap
command.
•
If devices are not properly displayed, you can use the SNC Manager
Advanced
page and the
route
command to manually map devices. Use the
route
command if devices have not been discovered
in order by the
autoMap
command. The LUN IDs should be in the order of the SCSI IDs.
•
For detailed troubleshooting procedures, refer to
Troubleshooting
on page 41.
•
If devices still are not properly displayed, contact ATAC.
5
Go to the
Restart
page.
6
Click
Restart
to make permanent any changes you have made since the last firmware restart.
Restarting the firmware can take a few minutes. Refer to
firmwareRestart
on page 62.
Other Ways of Connecting to and Monitoring the SNC
Using Telnet
Up to three Telnet sessions can be conducted simultaneously. A serial port session can use the CLI while
Telnet sessions are open. Whichever session issues the first “set” CLI command can continue to issue set
commands, while the other sessions can only issue “get” commands or display information. Once a
connection is established, refer to
Using the Command Line Interface (CLI)
on page 51 for lists of valid
commands.
1
Connect to the SNC from a computer on the same Ethernet network.
2
Start a Telnet session.
3
At the Telnet prompt, issue the
open
command:
telnet > open x.x.x.x
where x.x.x.x is the IP address of the SNC.
4
If you have to specify a port type, enter the port type
telnet
and the terminal type
vt100
.
Note
The recommended management tool for the SNC 450x is the SNC Manager
interface.
Note
There is more than one way to connect to the SNC using a Telnet
program.Your Telnet program may operate differently than in the following
instructions.
Note
To obtain the IP address of the SNC, refer to the information you recorded after
completing
Step 2
on page 22 in the section
Connecting to the Ethernet
Management Port
on page 21.
Содержание SNC 4500
Страница 1: ...www adic com ADVANCED DIGITAL INFORMATION CORPORATION SNC 450xUser sGuide...
Страница 6: ...vi Contents...
Страница 20: ...14 Getting Started Figure 4 Scalar 100 with Four LTO 1 or SDLT Drives...
Страница 23: ...SNC 450x User s Guide 17 Figure 6 Scalar 100 with Four LTO 2 Drives...
Страница 30: ...24 Getting Started...
Страница 46: ...40 Using the SNC Manager Interface...
Страница 112: ...106 Removal and Replacement Procedures...
Страница 116: ...110 iSCSI Performance Tuning...
Страница 119: ...SNC 450x User s Guide 113 BSMI Notice...
Страница 120: ...114 Regulatory Notices...