Scan Fiducials
The scan fiducials graphical report shows the results for tests of the fiducial barcode on each tape magazine
and drive sled, including the width, expected Y position (shift), and the number of hits the scanner receives
while traveling up and down. (Only known magazines are tested.)
•
If the graphical report shows a failed result for one or more tape magazines, replace the affected
magazines.
•
If there are multiple marginal or failed results, run the library alignment test (part of the installation
verification or partial frame test) to make sure the library properly aligned.
•
If the library is aligned and there are multiple marginal or failed results, the scanner should be
inspected and replaced if necessary.