Scalar i6000 Installation Guide
89
Removing and Replacing the IEX Card
If you are adding one or more expansion modules to an existing eight-module library, each expansion
module you are adding must contain an IEX2 card. The IEX2 card is identified by a red sticker. If an
expansion module you are adding contains an earlier version of the IEX card, you must remove the earlier
version and replace it with an IEX2 card.
Removing the IEX Board
Required Tools: None
FRU ID: 105 (IEX board)
1
If the library is not shut down, shut down the library.
For more information, see
2
Open the service door.
3
Attach the ESD strap to your wrist and to an unpainted surface inside the door.
4
Unscrew the thumbscrew and remove the LBX/IEX cover plate.
CAUTION
Only use this procedure if you are preparing to install expansion modules
to an existing eight-module library.
Note
New IEX2 cards are identified by red stickers. Earlier IEX card versions
have no stickers.
thumbscrew
Содержание Scalar i6000
Страница 1: ...6 66881 01 A Scalar i6000 Installation Guide Installation Guide Installation Guide Installation Guide...
Страница 20: ...8 About This Guide and Your Product...
Страница 38: ...26 Installing a Stand Alone Control Module...
Страница 104: ...92 Installing a Multi Module Library...
Страница 156: ...144 Installing Cartridges...
Страница 164: ...152 Setting up Your Library for Access...
Страница 242: ...230 Configuring the Library...
Страница 304: ...292 Adding Optional Hardware eight 2 5 mm screws...
Страница 318: ...306 Adding Optional Hardware...
Страница 336: ...324 Installation Testing and Verification Figure 35 Example Test Log Output...
Страница 356: ...344 Testing and Calibrating the Digital Level...
Страница 362: ...350 LBX Board and Terminator...
Страница 380: ...368 Glossary...
Страница 384: ...372 Index...