Preliminary
4-30
September 21, 1999
BENCHMARK
T A P E
S Y S T E M S
4.7
DLT Autoloader Error Messages
If an error occurs during operation of your DLT7 Autoloader, the autoloader stops the
current operation and displays an error message on the top line of the LCD panel. After you
solve the problem, cycle power on your DLT7 Autoloader and try the last operation again.
4.7.1 Error Message Listing
A description of each of the DLT Autoloader error messages is provided in the following
table:
Error Display
Description
SERIAL RCV
Inter-processor communication error
SRC EMPTY *
The source location is empty
DEST FULL *
The destination location is full
CPU RX ERR
The Motion CPU is not ready to receive
CPU TX ERR
The Motion CPU is not ready to transmit
SLOT EMPTY
No slot beam detected
PWR SWITCH
The front power switch was pressed
HALT
The Motion CPU has been halted by a low ACT line
CAM LIMIT
A cam limit has been reached without tripping a sensor
JAW SENSOR
A jaw sensor was tripped
INV MOV OP *
An invalid move operation occurred
REAR TAPE
A rear tape sensor was not tripped
FRONT TAPE
A front tape sensor was not tripped
REAR SLOT
A rear slot sensor was not tripped
FRONT SLOT
A front slot sensor was not tripped
PCKR FULL *
The Media Picker is full
PCKR EMPTY *
The Media Picker is empty
SLOT FULL *
Media present in slot
NVM SELECT
NVRAM selection failure
NVM WRITE
NVRAM write failure
DRIVE EJCT
Drive failed to eject media
DRIVE LOAD
Unable to load media into drive
DRIVE UNLD *
Drive not logically unloaded
DRIVE HNDL
Drive ‘Operate Handle’ timeout