Appendix A Specifications
72
ATL PowerStor L200 Series Library User’s Guide
Radiated Emissions
1
Table 23 lists the limits of radiated interference field strength, in the
frequency range from 30 MHz to 1000 MHz at a test distance of 10
meters, for Class B equipment.
Table 23 Radiated
Emissions (30 MHz to
1000 MHz)
Radiated Susceptibility
1
The radiated susceptibility limits for high frequency electric fields,
26 MHz to 1000 MHz, are:
•
3 V/m (rms) 80% modulated 1 kHz
•
no errors, no screen distortion. S/W recoverable errors
•
no hardware failure
Conducted Susceptibility
1
The transient voltage is the actual peak voltage above the normal AC
voltage from the power source.
The voltage limits for power and data cables are:
•
2 kV S/W recoverable errors
•
no hardware failures
The power cable voltage limits are:
•
2.0 kV common mode (no errors allowed)
•
1.0 kV differential mode (S/W recoverable errors, no hardware
failure)
Note: Maximum energy in a single pulse from the transient generator must
be limited to 2.5 W.
ESD Failure Level Limits
1
Table 24 lists the ESD failure level limits for normal operator access
areas.
Frequency Range = 30 MHz to
1000 MHz
Quasi-Peak Limit dB (uV/m) @ 10
meters
30 MHz to 230 MHz
30
230 MHz to 1000 MHz
37
Above 1000 MHz
Not applicable
Содержание ATL PowerStor L200 Series
Страница 1: ...ATL PowerStor L200 Series Tape Library for DLT Cartridges User s Guide 6322500 02 Ver 2 Rel 0...
Страница 4: ......
Страница 8: ...viii OCP Error Messages and Error Definitions 77...
Страница 10: ...Figures x ATL PowerStor L200 Series Library User s Guide...
Страница 12: ...Tables xii ATL PowerStor L200 Series Library User s Guide...
Страница 66: ...Chapter 3 Basic Library Operations Tests 50 ATL PowerStor L200 Series Library User s Guide...
Страница 92: ...Appendix A Specifications Reliability Factors 76 ATL PowerStor L200 Series Library User s Guide...
Страница 102: ...86 ATL PowerStor L200 Series Library User s Guide...
Страница 106: ...Index 90 ATL PowerStor L200 Series Library User s Guide...