Appendix B OCP Error Messages and Error Definitions
ATL PowerStor L200 Series Library User’s Guide
81
A4H
Time-out moving cartridge from the slot onto the elevator during a
Load Cartridge
command.
A5H
Time-out finding pusher home position during a
Load Cartridge
command.
A6H
Time-out moving elevator to drive-load position during a
Load Cartridge
command.
This error can be retried by issuing a
SCAN MAGAZINE
command, followed by reissuing the
Load Cartridge
command.
A7H
Time-out while opening the drives handle during a
Load Cartridge
command.
A8H
Time-out moving cartridge from the elevator into the drive during a
Load Cartridge
command.
If this occurs as the only error, then this error can be retried. The drive controller must first
unload the cartridge from the drive. Then it can reissue the command.
If this error occurs as the second error after either a
94H
or an
A9H
error, then this error is
considered fatal.
A9H
Time-out while attempting to find
PUSHPOS 2
to push cartridge completely into the drive
during a
Load Cartridge
command.
AAH
This code is not an error and will never be returned in the status error bytes. It is utilized in
the error trace buffer as an indicator every time a thousand cycles has occurred.
ABH
Time-out finding
PUSHPOS 1
(rack waiting position in front of the drive).
This error can be retried. The library controller must first unload the cartridge from the drive
then, reissue the command.
ACH
Time-out closing drive handle. This error can occur during a
Load Cartridge
command
or after error 94 if the loader controller tries to move the cartridge back into the drive.
ADH
Time-out leaving drive load position to move to drive park position.
AEH
Time-out while moving a cartridge back into a slot after error A4. This error could only
happen if the loader controller tries to move a cartridge from the slot onto the elevator and it
fails. The loader controller would then try to move the cartridge back into the slot. If that
fails, this error is generated.
AFH
Undefined error code.
B0H
Undefined error code.
B1H
Stand-alone mode.
B2H
Door open without getting a command. After power up this command can occur as the
loader remembers the state of the door.
This is an informational type error and does not require recovery.
B3H
Unit was reset or powered up.
This is an informational type error and does not require recovery.
Error Code
Description
Содержание ATL PowerStor L200 Series
Страница 1: ...ATL PowerStor L200 Series Tape Library for DLT Cartridges User s Guide 6322500 02 Ver 2 Rel 0...
Страница 4: ......
Страница 8: ...viii OCP Error Messages and Error Definitions 77...
Страница 10: ...Figures x ATL PowerStor L200 Series Library User s Guide...
Страница 12: ...Tables xii ATL PowerStor L200 Series Library User s Guide...
Страница 66: ...Chapter 3 Basic Library Operations Tests 50 ATL PowerStor L200 Series Library User s Guide...
Страница 92: ...Appendix A Specifications Reliability Factors 76 ATL PowerStor L200 Series Library User s Guide...
Страница 102: ...86 ATL PowerStor L200 Series Library User s Guide...
Страница 106: ...Index 90 ATL PowerStor L200 Series Library User s Guide...