ACL 4/52 Software Interface Guide
Document 6211225-03
Version 3.0
Introduction
A-7
Table is sorted by data in the ASC column
B
80
01
TRANSFER FULL - AT END OF PLACE
Gripper has cartridge in it at end of a place operation
(Move Medium with a target other than the Transfer).
Move cartridge to empty storage element using Move
Medium command. Retry command.
Both
B
80
06
TRANSFER EMPTY - COMMAND ABORTED
Gripper does not contain cartridge at end of pick
portion of Move Medium command.
Both
2
80
07
SYSTEM IS STOPPED (BUTTON IS CURRENTLY
PUSHED)
The Control Panel
STOP
button was pressed. Press the
STOP
button.
Both
6
80
07
SYSTEM STOP BUTTON WAS PRESSED (MAY
CURRENTLY BE PRESSED)
The Control Panel
STOP
button was pressed. Press the
STOP
button. Retry command.
Both
6
80
08
LOGICAL UNIT TURNED ON-LINE
The library is ready to communicate with the host
computer. Press the Control Panel
STANDBY
switch to
take the library off-line.
Diag
2
80
09
LOGICAL UNIT IS TURNED OFF-LINE
The library is ready to communicate with the diagnostic
PC. Press the Control Panel
STANDBY
switch to place
the library on-line.
SCSI
6
80
09
LOGICAL UNIT STANDBY BUTTON WAS PRESSED
Retry command.
SCSI
B
80
10
LOAD RETRY FAILED
ACL 4/52 was unable to successfully load the drive,
even after retries. Check drive alignment. If problem
continues, drive may need servicing.
Both
Sense
Key
ASC
ASCQ
Message Name/Description
Interface
Содержание ACL 4/52
Страница 1: ...ACL 4 52 Automated Tape Library for DLT Cartridges Software Interface Guide 6211225 03 Version 3 0...
Страница 2: ......
Страница 10: ...x...
Страница 14: ...1 2...
Страница 18: ...1 6...
Страница 36: ...3 2...
Страница 136: ...B 6...
Страница 138: ...C 2...
Страница 148: ...C 12...
Страница 150: ...D 2...