ACL 4/52 Software Interface Guide
Document 6211225-03
Version 3.0
A-2
Introduction
Table is sorted by data in the ASC column
Table A-1: Sense Data
Values (Hexadecimal)
Sense
Key
ASC
ASCQ
Message Name/Description
Interface
0
00
00
NO ADDITIONAL SENSE INFORMATION
No recovery necessary.
Both
B
00
00
SCSI ABORT
Command aborted because host sent SCSI Abort
Message.
SCSI
2
04
00
LU IS NOT READY, CAUSE NOT REPORTABLE
Check library unit power. Retry command.
Both
2
04
01
LOGICAL UNIT IN PROCESS OF BECOMING READY
Wait for library unit to complete initialization.
Both
2
04
03
LU IS NOT READY, MANUAL INTERVENTION
REQ’D
Initialization failed. Determine failure type by checking
any previous error code returned to host. Correct the
cause of the failure and toggle
STANDBY
switch.
Both
5
1A
00
PARAMETER LIST LENGTH ERROR
Invalid parameter list length field specified by
command.
SCSI
5
20
00
INVALID COMMAND OPERATION CODE
Verify host command format using the ACL 4/52
Software Interface Guide.
SCSI
5
21
01
INVALID ELEMENT ADDRESS
Check Mode Sense data for correct element addresses.
SCSI
5
24
00
INVALID FIELD IN COMMAND DATA BLOCK
Ensure all reserve fields are set to zero.
SCSI
Содержание ACL 4/52
Страница 1: ...ACL 4 52 Automated Tape Library for DLT Cartridges Software Interface Guide 6211225 03 Version 3 0...
Страница 2: ......
Страница 10: ...x...
Страница 14: ...1 2...
Страница 18: ...1 6...
Страница 36: ...3 2...
Страница 136: ...B 6...
Страница 138: ...C 2...
Страница 148: ...C 12...
Страница 150: ...D 2...