ACL 4/52 Software Interface Guide
Document 6211225-03
Version 3.0
A-12
Introduction
Table is sorted by data in the ASC column
4
84
23
VERTICAL POSITION OVERFLOW
The position step counter overflowed. Issue a Rezero
Unit command.
Both
4
84
24
VERTICAL HARDWARE ERROR
Vertical actuator or sensor has failed.
Both
4
84
30
VERTICAL MAPPING FAILURE
Scanner was unable to detect vertical target during
calibration.
Both
4
84
31
VERTICAL CONFIRMATION FAILURE
Unable to locate all confirmation flags. Check flag
sensor and cable connections. Check for obstructions on
vertical rail. If failure repeats, run vertical self-test.
Both
B
85
01
HORIZONTAL TIMEOUT
Horizontal axis did not reach desired position within
the time limits. Retry command. If failure repeats, use
the Diagnostic Software to run horizontal self-test.
Both
4
85
03
HORIZONTAL MECHANICAL POSITION ERROR
Horizontal axis did not reach desired position. Retry
command. If failure repeats, use the Diagnostic
Software to run horizontal self-test.
Both
4
85
08
HORIZONTAL HOME NOT FOUND
Horizontal axis did not reach the home position. Issue
Rezero Unit and retry command. If failure repeats, run
horizontal self-test.
Both
B
85
10
HORIZONTAL INVALID ACTUATOR START
POSITION
Position of horizontal axis is unknown. Issue a Rezero
Unit command.
Both
Sense
Key
ASC
ASCQ
Message Name/Description
Interface
Содержание ACL 4/52
Страница 1: ...ACL 4 52 Automated Tape Library for DLT Cartridges Software Interface Guide 6211225 03 Version 3 0...
Страница 2: ......
Страница 10: ...x...
Страница 14: ...1 2...
Страница 18: ...1 6...
Страница 36: ...3 2...
Страница 136: ...B 6...
Страница 138: ...C 2...
Страница 148: ...C 12...
Страница 150: ...D 2...