ACL 4/52 Software Interface Guide
Document 6211225-03
Version 3.0
A-4
Introduction
Table is sorted by data in the ASC column
-none-
OR
5
30
30
03
03
CLEANING CARTRIDGE INSTALLED
Indicates that the element contains a cleaning cartridge
that is not “used-up”. This is returned with the element
status data, which has no sense key.
OR
CLEANING CARTRIDGE INSTALLED
•
A cleaning cartridge cannot be removed from a
drive because it is being used in a cleaning
operation.
•
A cartridge cannot be placed into the drive because
the drive is being cleaned.
•
A cartridge cannot be placed into an empty storage
element because it is reserved for a cleaning
cartridge that is currently in use in a drive cleaning
operation.
SCSI
Both
5
39
00
SAVING PARAMETERS NOT SUPPORTED
Verify Save Parameter field in the Mode Sense
command complies with the command format
described in “Mode Sense (1Ah)” on page 3-25.
SCSI
5
3A
00
MEDIUM NOT PRESENT
The inventory indicated that a cartridge was in this bin
but no cartridge was sensed by the gripper when it
attempted to pick it. Retry the command. Check for
proper seating of the cartridge. It may also indicate that
the tape is not ready to be picked from the drive because
the tape is not fully unloaded. Retry the command. If
the problem persists, check the function of the tape
drive handle assembly. Manually unload the tape.
Both
Sense
Key
ASC
ASCQ
Message Name/Description
Interface
Содержание ACL 4/52
Страница 1: ...ACL 4 52 Automated Tape Library for DLT Cartridges Software Interface Guide 6211225 03 Version 3 0...
Страница 2: ......
Страница 10: ...x...
Страница 14: ...1 2...
Страница 18: ...1 6...
Страница 36: ...3 2...
Страница 136: ...B 6...
Страница 138: ...C 2...
Страница 148: ...C 12...
Страница 150: ...D 2...