BMC
SMASH
3-10
/SYS/powerSupply
This command provides the specification of the Sensor Type sensor-specific event.
*The sensor name list depends on the Server Hardware.
Q&A:
Q1: My system supports two power supply slots and only one power supply unit con-
nected. What is the other power supply status?
A1: The other power supply status is " AllDeasserted ".
Q2: My system supports two power supply slots and two power supply units connected.
But only one power cord plugged. What is the other power supply status?
A2: The other power supply status shows
"Presence Detected, Predictive Fail, Power
Supply Input Lost (AC/DC) "
.
BMC Information
The BMC level commands provide several options to configure and display parameters of
the management agent.
Displays information for the board
Table 3.7: /SYS/powerSupply
P
ROPERTY
N
AME
V
ALID
V
ALUE
A
CCESS
D
ESCRIPTION
Sensor name list
of power supply
Presence*
Power Supply Fail-
ure Detected*
Predictive Fail*
Power Supply
Input Lost (AC/DC)*
All Deasserted
(*Note: Only for
certain models.)
R
Presence Detected
indicates the Power Supply Presence detected
Power Supply Failure Detected
indicates the Power Supply Failure detected
Predictive Fail
indicates the Power Supply Predictive Failure
Power Supply Input Lost (AC/DC)
indicates the Power Supply input lost, such as power cord not inserted
All Deasserted
indicates the power supply is not inserted
Redundancy
Fully Redundant
Redundancy Lost
R
Fully Redundant
Indicates the power redundancy is OK.
Redundancy Lost
Indicates the power redundancy is fail. One PSU is removed or AC lost.
na
When system powered off, the state is not available.
Table 3.8: Targets and Verbs
R
ELATED
T
ARGETS
S
UPPORTED
V
ERBS
CD
EXIT
HELP
CREATE
DELETE
SET
SHOW
RESET
START
STOP
VERSION
/
v
v
v
v
v
/SP
v
v
v
v
v
v
v