BMC
M
AINTENANCE
G
ROUP
3-87
Step 4
: upgrade firmware
Step 5
: after Step 4, go to Step 2 and check if the event is still preserved
(if preserved then PASS, else FAIL)
3. IPMI
Step 1
: Please add a new user by Web.
Step 2
: check if the user added
Step 3
: go to Web-UI to check “IPMI” to be preserved
Step 4
: upgrade firmware
Step 5
: after Step 4, go to Step 2 and check if the user is still exist
(if preserved then PASS, else FAIL)
4. Network
Step 1
: Please change BMC IPv4 address source to be STATIC or DHCP mode by Web.
Step 2
: check if the mode changed
Step 3
: go to Web-UI to check
"
Network
"
to be preserved
Step 4
: upgrade firmware
Step 5
: after Step 4, go to Step 2 and check if the mode is still preserved
(if preserved then PASS, else FAIL)
5. SNMP (supported from Grantley platform)
Step 1
: Please go to add a new user and enable SNMP function.
Step 2
: check if the user added and SNMP function enabled
Step 3
: go to Web-UI to check “SNMP” to be preserved
Step 4
: upgrade firmware
Step 5
: after Step 4, go to Step 2 and check if the setting is still preserved
(if preserved then PASS, else FAIL)
6. SSH
Step 1
: Please go to add a new user and update the NEW SSH key.
Step 2
: check if the user added SSH key updated
Step 3
: go to Web-UI to check “SSH” to be preserved
Step 4
: upgrade firmware
Step 5
: after Step 4, go to Step 2 and check if the mode is still preserved
(if preserved then PASS, else FAIL)
7. KVM
Step 1
: Please modify the "Remote Session", "Mouse Mode", and "Virtual Media
Devices" setting by Web.
Step 2
: check if the setting changed