Attach
Flue First
CAK4A
Secure with Screws
Provided
Push Together
Secure to Top
C. Install Chimney Air kit (CAK4A)
NOTICE:
Chimney Air Kit, Part CAK4A is required when
using the SL-300 Pipe Series. Detailed instructions are
supplied with the kit. If using the Dura-Plus System (must
be 8 in./203 mm in diameter), the starter ring that came
with the fireplace must be removed and replaced with the
Dura-Plus Base Plate. The CAK4A is not required with a
Dura-Plus System.
• Install the chimney pipe first.
• Hand bend the tabs in position before placing on the
fireplace.
• Place the box on top of the fireplace around the chimney
pipe, push both pieces together and secure with screws
provided.
• Use the pre-punched holes in the tabs as guides and
drill holes through the fireplace top.
• Secure the CAK4A in place. See Figure 6.3.
• Seal around the kit at the flue and at the top of the can
with caulk. See Figure 6.3.
Figure 6.3 Installing the CAK4A
NOTICE:
Chimney sections cannot be disassembled once
locked together. Plan ahead!
• Lock chimney sections and/or offsets/returns together by
pushing downward until the top section meets the stop
bead on the lower section.
• Pull on the top section to make sure it is fully engaged
and will not separate.
• You may use #6 or #8 sheet metal screws no longer than
1/2 in. (13 mm) to fasten chimney sections together. Do
NOT penetrate inner flue.
WARNING!
Risk of Fire!
You MUST use screws (pro-
vided) to fasten offset/returns to chimney sections to
keep the chimney parts from twisting. Failure to do so
could cause fire.
• Fasten offset/returns to chimney sections. Insert the
screws (provided) through the predrilled holes. Do NOT
penetrate inner flue.
• Secure chimney returns with hanger straps provided;
fasten to studs or joists.
• Vertical straight runs of chimney must be supported every
35 ft (10.7 m).
B. Assemble Chimney Sections
Use only those components described in this manual.
Substitute or damaged chimney components could impair
safe operation and cause overheating and fire.
Attach either a straight chimney section or an offset to
the top of the fireplace (depending on your installation
requirement). Chimney sections are locked together by
pushing downward until the top section meets the stop
bead on the lower section.
The inner flue is placed to the inside of the flue section
below it. The outer casing is placed outside the outer cas-
ing of the chimney section below it. See Figure 6.2.
WARNING! Risk of Fire! DO NOT
install substitute or
damaged chimney components.
Figure 6.2 Assembling Chimney Sections
28