Hardware Installation
1. Product Overview
24
www.qtech.ru
Note:
1.
Exhaust vents for power modules
2.3.
Exhaust vents for service,
supervisor and switching fabric
modules
For the service modules, air flows across the chassis from the right intakes to the back vents.
For the power supply modules, air flows in from the front intakes and out from the back vents.
For the supervisor and switching fabric modules, air flows in from the bottom to the back
vents.
The chassis should be mounted in a place with sufficient space for air circulation. Maintain
a minimum clearance of 10cm around the chassis.
If any module slot is unoccupied, install a filler panel to ensure proper airflow.
1.4
Module
The QSW-7600 switch adopts the module-based design. Compliant with industry standards,
the design divides modules and integrates module interfaces to ensure the switch system's
functioning and independence of various function modules.
The modules of the QSW-7600 switch provide 10/100/1000M auto-sensing Ethernet copper
ports, 1000 Mbps/100 Mbps SFP (single-mode/multi-mode) optical fiber interfaces and
10G/40G optical fiber interfaces.
1.4.1
QSW-M7608-CM
QSW-M7608-CM is the supervisor module of the QSW-7608 series switches and is designed
with management and switching functions.