Hardware Installation
11. Appendix C Cabling Recommendations in Installation
130
www.qtech.ru
Figure C-3 Do Not Tie Cable Ties within the Bend
❖
Wrap up unnecessary or excess cables and bind them to the appropriate rack position,
where device operation is not affected and no damages occur to the device and cables
during debugging.
❖
Do not bind power cords to the rails for moving parts.
❖
Leave a certain length of the cable connecting moving parts, such as the ground wire of the
cabinet door, to avoid stress on the cable; When moving parts are in place, ensure the
excess cable length shall not contact heat sources, sharp corners or edges. If heat sources
are unavoidable, use high-temperature cables instead.
❖
When using screws to fasten cable lugs, the bolts or nuts shall be tightened and prevented
from loosening, as shown in Figure C-4.
Figure C-4 Fastening Cable Lugs
Note
1.
Flat washer
2.
Nut
3.
Spring washer
4.
Flat washer