Hardware Installation
7. Replacing Modules
114
www.qtech.ru
7
REPLACING MODULES
7.1
Removing, Cleaning and Installing Air Filter
After the air filter is used for a long time, the dust may block the holes on the air filter,
affecting heat dissipation and ventilation. It is recommended that the air filter be cleaned
every three months.
7.1.1
Removing, Cleaning and Installing Air Filters for Supervisor and Service Modules
❖
Install the air filter of QSW-7608 supervisor and service modules:
1.
Insert the air filter along the slide rail. Pay attention to the direction instruction on the air
filter.
2.
Tighten the screws on the air filter with a screwdriver.
❖
Remove the air filter of QSW-7608 supervisor and service modules:
1.
Loosen the captive screws on the air filter.
2.
Remove the air filter.
3.
4.
Figure 7-1 Installing and Removing the Air Filter of QSW-7608 Supervisor and Service
Modules
5.
Note
A: Air filters to be removed
B: Air filters to be installed
7.2
Removing Swappable Interface Modules (Optional)
7.2.1
Removing SFP+/SFP Modules
Take the following steps to remove SFP/SFP+ modules:
1.
Unplug the optical fiber.