PROGRAMMING
INSTALLER/DEALER SETTINGS
Setting
Default
Description
EN Grade 2
Disabled
This setting is required for EN Grade 2 compliance on the Panel and must be Enabled for
EN Grade 2 installations. When Enabled, the following behaviors and/or settings are
changed automatically:
- Entry Procedure (EU) - follows entry procedures and alarm transmission delays
specified by EN 50131
- Disables the “Auto Bypass” setting so that the Panel will protest arming when sensor
and panel trouble conditions are present (i.e. Open, Tamper, Low Battery, etc)
- Trouble condition alerts can not be acknowledged until the condition is resolved
- Trouble beeps are expanded to include fault indications required by EN 50131
- “Screen Lock” setting is enabled automatically. Screen will lock 30 seconds after
Disarming
- A new icon called “EU Events” is added to the “Settings" page which records mandatory
history events specified by EN 50131.
- “Loss of Supervisory Signals for PowerG Non-Emergency Sensors” is set to 2 hours by
default.
- “LED Indicator” setting is Disabled automatically.
- “Partitions” setting is not available.
- “Dealer or Installer Access Requires User Permission” setting is Enabled automatically.
EU Event Swinger Shutdown Count
3
Determines the number of times a particular event will record to “EU Events” log before
shutdown. The count (3-10) will reset after and arm or disarm event.
NOTE:
This setting is
greyed out and not selectable unless EN Grade 2 is Enabled.
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE OF
30
173
Содержание Panel 2+
Страница 8: ...INSTALLING THE PANEL...
Страница 13: ...USER INTERFACE...
Страница 17: ...PROGRAMMING...
Страница 52: ...SECURITY SENSORS...
Страница 84: ...WI FI DEVICES...
Страница 91: ...Z WAVE DEVICES...
Страница 102: ...BLUETOOTH DEVICES...
Страница 110: ...SYSTEM TESTS...
Страница 134: ...CUSTOMIZATION...
Страница 147: ...MAINTENANCE...
Страница 153: ...TROUBLESHOOTING...
Страница 163: ...LEGAL...
Страница 169: ...SPECIFICATIONS...