SYSTEM TESTS
Z-WAVE TESTS
COUNTER
DESCRIPTION
Acked commands no
auto route
Command was successful and acknowledged by the sensor; it did not use the normal automatic Z-Wave network route
to execute the command for this device (command was re-routed on the Z-Wave network in order to succeed)
Acked commands auto
route
Command was successful and acknowledged by the sensor;
it used the normal automatic Z-Wave network route to
execute the command for this device.
Failed commands
network failed
Not possible to transmit data because Z-Wave network is busy (jammed). Command failed to execute.
Network failed
Not possible to transmit data because Z-Wave network is busy (jammed). Command failed to execute
Network not idle
Auto-routed command failed because Z-Wave network is not yet stable.
Command failed to execute.
Network no route
Auto-routed command failed because there is no successful Z-Wave network route to the device.
Command failed to
execute
Reset All
Resets all counters back to 0 as to better diagnose the network
Details
Shows individual device details such as passed and failed commands. Here you can also reset an individual device’s
counter
QOLSYS CONFIDENTIAL AND PROPRIETARY
PAGE
OF
124
173
Содержание Panel 2+
Страница 8: ...INSTALLING THE PANEL...
Страница 13: ...USER INTERFACE...
Страница 17: ...PROGRAMMING...
Страница 52: ...SECURITY SENSORS...
Страница 84: ...WI FI DEVICES...
Страница 91: ...Z WAVE DEVICES...
Страница 102: ...BLUETOOTH DEVICES...
Страница 110: ...SYSTEM TESTS...
Страница 134: ...CUSTOMIZATION...
Страница 147: ...MAINTENANCE...
Страница 153: ...TROUBLESHOOTING...
Страница 163: ...LEGAL...
Страница 169: ...SPECIFICATIONS...